Siemens RUGGEDCOM RS900W Installation Manual page 42

Wireless ethernet switches
Table of Contents

Advertisement

Chapter 6
Certification
Test
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-29
IEC 61000-4-11
IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
IEC 60255-5
32
Description
Induced (Conducted) RFI
Magnetic Field
Voltage Dips and Interrupts
Voltage Dips and Interrupts
Damped Oscillatory
Mains Frequency Voltage
Ripple on DC Power Supply
Dielectric Strength
HV Impulse
DC Power Ports
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
AC Power Ports
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
Signal Ports
DC Power Ports
AC Power Ports
Earth
Ground Ports
Enclosure Ports
40 A/m Continuous
DC Power Ports
AC Power Ports
100% for 5 Periods
100% for 50 Periods
Signal Ports
2.5 kV Common Mode @ 1 MHz
1 kV Differential Mode @ 1 MHz
DC Power Ports
2.5 kV Common Mode @ 1 MHz
1 kV Differential Mode @ 1 MHz
AC Power Ports
2.5 kV Common Mode @ 1 MHz
1 kV Differential Mode @ 1 MHz
Signal Ports
DC Power Ports
DC Power Ports
Signal Ports
2 kV (Failsafe Relay Output)
DC Power Ports
AC Power Ports
Signal Ports
5 kV (Failsafe Relay Output)
DC Power Ports
AC Power Ports
Installation Guide
Test Levels
10 V
10 V
10 V
10 V
1000 A/m for 1 s
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
30 V Continuous
300 V for 1 s
30 V Continuous
300 V for 1 s
10%
1.5 kV
2 kV
5 kV
5 kV
EMC and Environmental Type Tests
RUGGEDCOM RS900W
Severity Levels
3
4
3
3
3
3
3
3
3
4
4
3

Hide quick links: