Troubleshooting
TYPE OF PROBLEM
Sprayer does not run at all
Display shows CODE 05
Control board status light blinks
5 times repeatedly
30
WHAT TO CHECK
Control is commanding motor to run
but motor shaft does not rotate.
Possibly locked rotor condition,
an open connection exists between
motor and control, there is a problem
with motor or control board, or
motor amp draw is excessive.
HOW TO CHECK
6.
Perform Field Short Test: Test at large 4-pin motor
field connector. There should not be continuity from
pin 4, the ground wire, and any of the remaining
3 pins. If motor field connector tests fail,
replace motor.
7.
Check Motor Thermal Switch: Unplug thermal
wires. Set meter to ohms. Meter should read the
proper resistance for each unit (see table below).
-
ti13140a
Resistance Table:
695/240V Mark IV
795/120V Mark IV
1095/240V Mark V
1595/120V Mark V/MARK VII
MARK X
0 ohms
2k ohms
3.9k ohms
6.2k ohms
10.0k ohms