J Program example
Example 1:
I/O data transfer from a slave station of the FP1 MEWNET-TR system to FP3/FP10S master A
When R0 of FP3/FP10S master A turns ON,
input data from the 16-point input slave station
(station No. 0) of the FP1 MEWNET-TR
system is transferred to internal relay R63F of
FP3/FP10S master A.
Example 2:
I/O data transfer from FP3/FP10S master A to a slave station of the FP1 MEWNET-TR system
When timer relay T0 of FP3/FP10S master A
turns ON, an output is generated from terminal
F of station No. 0 of the 16-point output slave
station of the FP1 MEWNET-TR system.
6-3. I/O Link Application Examples
X30
R0
X0
T0
X70
FP1
Y70
MEWNET - TR
R63F
FP3/FP10S
Master A
Y20
FP3/FP10S
Master A
Y3F
FP1
MEWNET - TR