GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
Altitude (FT)
Max. Input (BTU/HR)
Max. Output Steady State (BTU/HR)
Efficiency (w/the fan on)
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow Conditions)
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
Never obstruct the front opening of the appliance.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance
and shall be installed.
2.5

RATING PLATE INFORMATION

CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
DIRECT VENT VENTED GAS FIREPLACE. APPROVED FOR BEDROOM, BATHROOM & BEDSITTING
ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN
ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED
MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME
CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US
STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR
MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
FOR USE WITH BARRIER W565-0156. FOLLOW THE INSTALLATION INSTRUCTIONS
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
COLONNE D'EAU(GN)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE
COLONNE D'EAU (GN)
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 7" D'UNE
COLONNE D'EAU (GN)
NOT FOR USE WITH SOLID FUEL
CAUTION: FOR USE WITH GLASS DOORS
CERTIFIED WITH THIS UNIT ONLY.
WARNING: DO NOT ADD ANY MATERIAL TO
THE APPLIANCE, WHICH WILL COME IN CONTACT
WITH THE FLAMES, OTHER THAN THAT SUPPLIED
BY THE MANUFACTURER WITH THE APPLIANCE.
THIS VENTED GAS FIREPLACE IS NOT
FOR USE WITH AIR FILTERS.
DECORATIVE PRODUCT: NOT FOR USE AS A
HEATING APPLIANCE
ELECTRICAL RATING: BLOWER KIT GS67, 115V
0.5AMP 60HZ THE APPLIANCE MUST BE VENTED
USING THE APPROPRIATE WOLF STEEL VENT
KITS. SEE OWNERS INSTALLATION MANUAL FOR
VENTING SPECIFICS. MINIMUM AND MAXIMUM
VERTICAL VENT LENGTHS ARE 3 FEET AND 40
FEET RESPECTIVELY.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
The rating label is located behind the control door and is chained to the appliance. DO NOT REMOVE. For
rating plate location, see "INSTALLATION OVERVIEW" section.
MATERIAL: CLASS IIIA-2 PERMANENT LABEL, WATERPROOF, 10 MIL VELVET GLOSS LEXAN
HOLE TO BE 0.250"Ø
BLACK ON WHITE BACKGROUND
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
MAX OVERALL DECAL SIZE: 8.5"x4.75"
SERIAL NUMBERS TO BE ASCENDING FROM GDS26002600
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
WOLF STEEL LTD.
TITLE:
RATING PLATE, GDS26 (SB)
APPLIANCE
4.5" Water Column (11mb)
13" Water Column (32mb)
3.5" Water Column (9mb)
LOCATED IN THE INSTALLATION MANUAL
9700539 (WSL)
4001658 (NAC)
GDS26N
CDVS26N
0-4500ft
ALTITUDE / ELEVATION
25,000 BTU/h
INPUT / ALIMENTATION
17,000 BTU/h
REDUCED INPUT /ALIMENTATION REDUITE
61.3%
MINIMUM AND MAXIMUM HORIZONTAL VENT
LENGTHS ARE 10 INCHES AND 20 FEET
RESPECTIVELY. PROPER REINSTALLATION AND
RESEALING IS NECESSARY AFTER SERVICING
THE VENT-AIR INTAKE SYSTEM.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL:
A
2"
B
5"
C
2"
VENT TOP
2"
TO CEILING FROM
VENT BOTTOM
1"
STOVE TOP
12"
VENT SIDES
1"
NG
0-4,500
25,000
20,500
82%
FOYER À GAZ VENTILÉS À ÉVACUATION DIRECTE. HOMOLOGUE POUR INSTALLATION DANS
UNE CHAMBRE A COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR
INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION CONFORME AUX EXIGENCES
DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN
VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE
CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS
LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER A LA
NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR
LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES SITES ET LES
COMMUNAUTES, ANSI/NFPA 501A. POUR UNE UTILISER AVEC BARRIÈRE W565-0156.
SUIVEZ LES INSTRUCTIONS D'INSTALLATION SE TROUVENT DANS LE MANUEL
D'INSTALLATION.
4001657 (NGZ)
4001659 (WUSA)
GDS26P
CDVS26P
0-4500ft
25,000 BTU/h
20,000 BTU/h
61.3%
P4
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILSE AVEC CET APPAREIL
ATTENTION: UTILISER AVEC LES PORTES VITREES
HOMOLOGUEES SEULEMENT AVEC CETTE UNITE.
AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL AUCUN
MATERIAU DEVANT ENTRER EN CONTACT AVEC LES
FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET
APPAREIL PAR LE FABRICANT. CE FOYER À GAZ VENTILÉS NE
DOIT PAS ÊTRE UTILISÉ CONJOINTEMENT AVEC DES FILTRES
À AIR.
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPARIEL
DE CHAUFFAGE.
CLASS.: SOUFFLERIE GS67, 115V 0.5AMP
60HZ L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPRE A WOLF STEEL.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE
POUR L'EVACUATION PRECISE. LES LONGUEURS
VERTICALES MINIMALES ET MAXIMALES SONT 3 PIEDS ET 40
PIEDS RESPECTIVEMENT.
SERIAL NUMBER / NO. DESERIE
GDS26
P
0-4,500
25,000
20,500
82%
11" Water Column (27mb)
13" Water Column (32mb)
10" Water Column (25mb)
MANIFOLD PRESSURE: 10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR: 10" D'UNE
COLONNE D'EAU (P)
MIN SUPPLY PRESSURE: 11" W.C. (LP)
PRESSION D'ALIMENTATION MIN: 11" D'UNE
COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 13" D'UNE
COLONNE D'EAU (P)
LES LONGUEURS HORIZONTALES MINIMALES ET
MAXIMALES SONT 10 POUCES ET 20 PIEDS
RESPECTIVEMENT.
IL EST IMPORTANT DE BIEN REINSTALLER ET
RESCELLER L'EVENT APRES AVOIR ASSURE LE
MAINTIEN DU SYSTEME DE PRISE D'AIR.
DEGAGEMENTS MINIMAUX DES MATERIAUX
COMBUSTIBLES:
A
2"
B
5"
C
2"
EVENT SUPERIEUR
2"
ENTRE LE DESSUS
DU FOYER
EVENT INFERIEUR
1"
ET LE PLAFOND 12"
COTES DE L'EVENT
1"
W385-1963
W415-2183 / B / 02.10.17
PAGE 1 OF 2
DWG#: W385-1963