Input; Output; Operating Conditions - Siemens SITRANS WFS320 Operating Instructions Manual

Sensing heads
Table of Contents

Advertisement

Technical Data

9.3 Input

Cable
for connection between conditioner card and
integrator
Cable
for connection between LVDT and LVDT condi-
tioner card when remotely or integrator mount-
ed
Belden is a registered trademark of Belden Wire & Cable Company.
1
6 conductor cable to be used with SIWAREX FTC.
2
9.3
Input
Power
± 5 V DC (typically from a Siemens integrator)
LVDT conditioner card
Input
0 to 0.75 V AC from LVDT
LVDT conditioner card
9.4

Output

Output
0 to 50 mV DC to Siemens integrator; maximum 300 m (1000 ft) separation between conditioner
LVDT conditioner card
card and integrator
Output
0 - 0.75 V AC @ 2.9 kHz
LVDT
LVDT excitation
2.50 V AC @ 2.9 kHz (supplied by integrator or LVDT conditioner card)
9.5

Operating conditions

Ambient temperature
-40 to +60 °C (-40 to +140 °F)
-40 to +50 °C (-40 to +122 °F) with optionally internally mounted LVDT card
40
Belden
8404, 4 conductor, shielded
®1
20 AWG (0.5mm
) or equivalent
2
Belden 9260, 6 conductor
, shielded 20 AWG
2
(0.5 mm
) or equivalent
2
Belden 9260, 6 conductor, shielded 20 AWG
(0.5 mm
) or equivalent
2
150 m (500 ft)
maximum
300 m (1000 ft)
maximum
300 m (1000 ft)
maximum
Operating Instructions, 02/2016, A5E32880290-AB