Wiring Diagram - Amana AVPTC 24B14A Series Manual

Multi-position, variable-speed, ecm-based air handler with internal txv comfortnet compatible 1 1/2 to 5 tons

Advertisement

40 VA TRANSFORMER, SEE NOTE 1
PL1
PL2
230 VAC
RD
2
2
RD
208 VAC
3
3
BK
1
1
BK
6
6
WH
BR
5
5
BL
4
4
7
7
C
8
8
9
9
4 CIRCUIT HEATER
SEE
CONNECTOR
NOTE 7
SEE NOTE 5
BK
SEE NOTE 6
RD
4
3
2
BL
1
GY
BK
RD
TWO-STAGE INTEGRATED CONTROL MODULE
ECM MOTOR
HARNESS
NOTES:
1. PLACE RED WIRES ON TRANSFORMER TERMINAL 2 FOR 208 VAC OPERATION.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THIS UNIT MUST BE REPLACED,
IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT
LEAST 105°C. USE COPPER CONDUCTORS ONLY.
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C AND LOCAL CODES.
5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS
SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS)
6. RED STATUS LED PROVIDES NETWORK STATUS. GREEN RX LED INDICATES NETWORK TRAFFIC.
USE LEARN BUTTON TO RESET NETWORK.
7. DISCARD CONNECTOR PL1 WHEN INSTALLING OPTIONAL HEAT KIT.
8. THE CONDENSATE ALARM SWITCH (CAS) TERMINALS CAN ONLY BE UTILIZED WITH COMMUNICATING
MODE SETUPS AND MUST BE ENABLED WITH A COMMUNICATING THERMOSTAT. THIS FEATURE IS NOT
OPERATIONAL WITH LEGACY SYSTEMS.
USE N.E.C CLASS 2 WIRE.
Wiring is subject to change. Always
refer to the wiring diagram on the
unit for the most up-to-date wiring.
SS-AAVPTC
RD
GRND
3
24 VAC
2
COM
1
BL
RD
W2 W1
TR
TH
COM
24 V 3 A
FUSE
LEARN
FAULT
SEE NOTE 6
RECALL
CAS
STATUS
SEE NOTE 8
LED
7 SEGMENT
DIAGNOSTIC
DEHUM
DISPLAY
O
CFM LED
SEE NOTE 6
Y2
RX LED
Y1
W2
W1
G
C
R
S1 S2 S3 S4
S5 S6 S7 S8 S9 S10 S11 S12 S13
DIP SWITCHES
2
1
CIRCULATOR BLOWER
4 3 2 1
1
2
GN
3
4
5
RD
BK
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
Warning
sources may be present. Failure to do so may cause property damage, personal injury, or death.
www.amana-hac.com
L1
GN
DISCONNECT
BL
L1
FUSE 3 A
TH
R
W1 (1)
W1
W2 (2)
W2
CAS (1)
Y1
CAS (2)
TO
Y2
MICRO
+VDC (1)
RX (2)
O
DEHUM
GRND (4)
C
TR
COM
INTEGRATED CONTROL MODULE
GRND
INTEGRATED CONTROL
LOW VOLTAGE (24V)
LOW VOLTAGE FIELD
HI VOLTAGE (230V)
HI VOLTAGE FIELD
JUNCTION
TERMINAL
INTERNAL TO
EQUIPMENT GRND
FIELD GRND
FIELD SPLICE
RESISTOR
OVERCURRENT
PROT. DEVICE
PLUG CONNECTION
Wiring Diagram – Air Handler
L2
GRND
INDOOR
AIR
CIRCULATOR
BLWR
GRND
208/230 VAC
L2
40 VA
TRANSFORMER
24 VAC
HEAT 1 COIL/R1
HEAT 2 COIL/ R2
CONDENSATE SWITCH
INDOOR
AIR
CIRCULATOR
BLWR
GRND
COLOR CODES:
PK ---- PINK
BR ---- BROWN
WH ---- WHITE
BL ---- BLUE
GY ---- GRAY
RD ---- RED
YL ---- YELLOW
OR ---- ORANGE
PU ---- PURPLE
GN ---- GREEN
BK ---- BLACK
0140A00244-B
13