Fluke TiR2 User Manual page 103

Ir flexcam thermal imagers
Hide thumbs Also See for TiR2:
Table of Contents

Advertisement

Model Name
Calibrated
Temp.
Ranges
Accuracy
Measurement
Modes
Emissivity
Correction
Battery Type
info@Fluke-Direct.com
Table D-1. TiR2, Ti45 and Ti40 Specifications (cont.)
Ti45 and TiR2
Temperature Measurement
Range 1 = -20 °C to 100 °C
(-4˚F to 212˚F)
Range 2, 3, and 4 are not
available on the TiR2
Range 2 = -20 °C to 350 °C
(-4 °F to 662 °F)
Range 3 = 250 °C to 600 °C
(482˚F to 1112˚F)
Range 4 = 500 °C to 1200 ˚C
(932 °F to 2192 °F) (option)
±2 °C or ±2 %, whichever is greater
Movable points & boxes
Centerpoint
Cursor temp.
Center box (area min/max,
average)
Automatic hot and cold
point detection
Color alarm
Based on user input. Variable from 0.01 to 1.0
(0.01 increments)
Li-Ion Smart Battery, rechargeable, field-replaceable
Fluke-Direct
Camera Specifications and Dimensions
Range 1 = -20 °C to 100 °C
(-4˚F to 212˚F)
Range 2 = -20 °C to 350 °C
(-4 °F to 662 °F)
Centerpoint
Cursor temp.
Center box (area min/max,
average)
Power
Appendices
Ti40
.com
1.888.475.5235
D
D-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tir3Tir4Ti40Ti45Ti50Ti55