Main Circuit Wire Gauges And Tightening Torque - YASKAWA U1000 iQpump MATRIX Drive User Manual

Low harmonic regenerative pump controller
Hide thumbs Also See for U1000 iQpump MATRIX Drive:
Table of Contents

Advertisement

A – Main circuit terminal
u

Main Circuit Wire Gauges and Tightening Torque

Use the tables in this section to select the appropriate wires and crimp terminals.
Gauges listed in the tables are for use in the United States.
Note:
Wire gauge recommendations based on drive continuous current ratings (ND) using 75 °C (167 °F) 600 Vac vinyl-sheathed wire assuming
ambient temperature within 40 °C (104 °F) and wiring distance less than 100 m.
Consider the amount of voltage drop when selecting wire gauges. Increase the wire gauge when the voltage drop is greater
than 2% of motor rated voltage. Ensure the wire gauge is suitable for the terminal block. Use the following formula to calculate
the amount of voltage drop:
Line drop voltage (V) = 3 × wire resistance (Ω/km) × wire length (m) × current (A) × 10
Refer to UL Standards Compliance on page 412
The wire gauges listed in the following tables are Yaskawa recommendations. Refer to local codes for proper wire gauge
selections.
n
Three-Phase 200 V Class Drives
Table 3.3 Drive Wire Gauge and Torque Specifications (Three-Phase 200 V Class)
Drive
Terminal
Model
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
2o0028
p1, n1
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
2o0042
p1, n1
YASKAWA TOEPYAIUPW01A YASKAWA AC Drive - U1000 iQpump Matrix Drive User Manual
A
Figure 3.24 Protective Cover Example (Drive Model 2o0104)
for information on UL compliance.
For USA and Canada
Recomm. Gauge
Wire Range
2
mm
mm
(AWG, kcmil)
(AWG, kcmil)
10
6 to 10
(8)
(10 to 8)
10
6 to 10
(8)
(10 to 8)
10
6 to 16
(8)
(10 to 6)
2.5
2.5 to 4
(14)
(14 to 12)
16
10 to 25
(6)
(8 to 3)
16
10 to 25
(6)
(8 to 3)
10
6 to 25
(8)
(10 to 3)
2.5
2.5 to 4
(14)
(14 to 12)
B – Terminals p1 and n1
For South America
Recomm. Gauge
2
2
mm
(AWG, kcmil)
4
(12)
4
(12)
6
(10)
2.5
(14)
10
(8)
10
(8)
10
(8)
2.5
(14)
3.8 Main Circuit Wiring
B
-3
Screw
Wire Range
Size
2
mm
(AWG, kcmil)
2.5 to 10
M5
(14 to 8)
(20.4 to 23.9)
2.5 to 10
M5
(14 to 8)
6 to 16
M6
(10 to 5)
(34.7 to 43.4)
2.5 to 4
M4
(14 to 12)
6 to 25
M6
(10 to 3)
(35.4 to 53.1)
6 to 25
M6
(10 to 3)
6 to 25
M8
(10 to 3)
(78.1 to 95.5)
2.5 to 4
M4
(14 to 12)
Tightening
Torque
N·m (lb.in.)
3
2.3 to 2.7
3.9 to 4.9
1 to 1.4
(8.9 to 12.4)
4 to 6
8.8 to 10.8
1 to 1.4
(8.9 to 12.4)
67