123B/124B/125B
Users Manual
Do not apply more than one phase of a
multiphase system simultaneously to
any COM
˜
(common) connection. All
Common (COM) connections should be
equipotential, as
Remove the batteries if the Product is
not used for an extended period of time,
or if stored in temperatures above 50 °C.
If the batteries are not removed, battery
leakage can damage the Product.
The battery door must be closed and
locked before you operate the Product.
Comply with local and national safety
codes. Use personal protective
equipment (approved rubber gloves, face
protection, and flame-resistant clothes)
to prevent shock and arc blast injury
where hazardous live conductors are
exposed.
Do not apply more than the rated
voltage, between the terminals or
between each terminal and earth ground.
2
marked.
Limit operation to the specified
measurement category, voltage, or
amperage ratings.
Use Product-approved measurement
category (CAT), voltage, and amperage
rated accessories (probes, test leads,
and adapters) for all measurements.
Measure a known voltage first to make
sure that the Product operates correctly.
Use the correct terminals, function, and
range for measurements.
De-energize the circuit or wear personal
protective equipment in compliance with
local requirements before you apply or
remove the flexible current probe from
hazardous live conductors.
Do not touch voltages > 30 V ac rms,
42 V ac peak, or 60 V dc.
Do not use the Product around explosive
gas, vapor, or in damp or wet
environments.