Auto Page RF-502 Operation Instructions Manual

Auto page rf-502 operation instructions

Advertisement

Quick Links

RF-502
OPERATION INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Auto Page RF-502

  • Page 1 RF-502 OPERATION INSTRUCTIONS...
  • Page 2 AutoPage and Iwata maintain the long tradition of providing the best value to their customers. We sincerely hope the purchase of the RF-502 vehicle security system provides peace of mind to you. Please take the time to read over this operation manual to thoroughly familiarize yourself with the many features and options of the RF-502.
  • Page 3 RF-502 OPERATION INSTRUCTIONS REMOTE CONTROL TRANSMITTER OPERATION The new remote control transmitter (XT-54) included with the RF-502 offers the code rolling feature which will prevent illegal use of a code- grabber with an attempt to record the code of your transmitter.
  • Page 4: Panic Function

    3. PANIC FUNCTION The RF-502 remote control may be used as a remote panic switch to trigger the siren in cases of emergency. To activate the PANIC FUNCTION press and hold the ON/OFF button on the remote transmitter for a minimum of 3 seconds.
  • Page 5 4. LED FLASHING= The RF-502 is armed. 5. LED FLASHING IN A 2 FLASH/HOLD SEQUENCE= Alarm breach. NOTE: Unless a door is opened after disarming, the RF-502 will automatically rearm in 60 seconds, and the LED will continue to flash.
  • Page 6: Override Function

    NOTE: Both VALET and OVERRIDE functions are performed from the same switch. 1. OVERRIDE FUNCTION The OVERRIDE FUNCTION may be used if the RF-502 remote is lost or inoperative. To operate the OVERRIDE FUNCTION, enter the vehicle (siren will sound); switch the vehicle ignition to ON. Move the VALET/OVERRIDE switch to ON;...
  • Page 7: Passive Arming

    If you choose the MANUAL (active) arming mode, follow the steps below. 1. Switch off ignition, leave vehicle, and close all protected openings. 2. Press the ON/OFF button on the remote transmitter. 3. The siren will chirp 1 time. 5 seconds later the RF-502 will be fully armed. PASSIVE/MANUAL DISARMING OPERATION...
  • Page 8: Automatic Rearming

    However, the doors will lock in manual arming and automatic re-arming. TRIGGER TEST After arming the RF-502 in either the PASSIVE or MANUAL mode, test the system in the following manner.
  • Page 9 3. If optional sensors have been installed, arm the RF-502 and test according to the directions of the particular sensor installed. If triggered in the armed condition, the RF-502 will sound its siren and flash the lights for 60 seconds; then it will stop and automatically reset and rearm.
  • Page 10 ON/OFF button of the third and/or fourth transmitters. The RF-502 can learn up to four remote transmitter codes. If later optional third and forth transmitters are to be programmed, follow sequence 1 through 6 and re-program all existing transmitters.
  • Page 11 NOTE: Here, the first transmitter is assumed to be the primary transmitter of Vehicle #1, and the second transmitter is assumed to be the primary transmitter of Vehicle #2. TRANSMITTER #1 TRANSMITTER #2 VEHICLE #1 ON/OFF BUTTON AUX BUTTON RF-502 VEHICLE #2 AUX BUTTON ON/OFF BUTTON...
  • Page 12 The RS-32 utilizes microwave technology that emits dual protective fields. The easy and separate adjusment of the exterior and interior fields allows the RF-502 to be armed and provide maximum protecti on in convertible vehicles parked with the top down, and equally good protection in enclosed vehicles.
  • Page 13 RK-1 Relay Kit A pre-wired relay and socket for starter interrupt and other functions of the RF-502. As an option to the standard single tone siren package, a six tone siren is available at additional cost. XT-54 EXTRA REMOTE CONTROL TRANSMITTER...
  • Page 14 LIMITED LIFETIME WARRANTY PROVISIONS (U.S. and Continental U.S. Only) 1. AutoPage, Inc. WARRANTS that this new unit has been thoroughly inspected and tested at the factory prior to delivery. Your AutoPage equipment is guaranteed for "life" to the original purchaser/user of the equipment under the following conditions: If the product proves defective (according to AutoPage's testing) within the first year, the defective unit may be exchanged or repaired free of charge.
  • Page 15 RF-502 7 AutoPage shall not be liable, under the foregoing WARRANTIES or otherwise, for: Any personal injury of any kind to the purchaser, its employees or agents or anyone else whomsoever resulting directly or indirectly from the use or presence of the equipment or parts; Consequential damages of any kind; Any...
  • Page 16 This WARRANTY CARD is for your record. However, AutoPage reserves the right to request you to submit this WARRANTY CARD which must have complete information to receive warranty service. Please keep this card in a secured place. AUTOPAGE WARRANTY SERVICE CARD Model RF-502 CUSTOMER TO COMPLETE Mr/Mrs/Ms __________________________...
  • Page 17 DATE SERVICE COMPLETED...
  • Page 18 1815 W. 205th St. #101 Torrance, CA 90501 310-618-2002...

Table of Contents