Ipv4-Flow-Table-Size - Juniper EX9200 Features Manual

Flow monitoring feature guide ex series
Hide thumbs Also See for EX9200:
Table of Contents

Advertisement

Flow Monitoring Feature Guide for EX9200 Switches

ipv4-flow-table-size

Syntax
Hierarchy Level
Description
Options
Required Privilege
Level
Release History Table
Related
Documentation
38
ipv4-flow-table-size units;
[edit chassis fpc slot-number inline-services flow-table-size]
Configure the size of the IPv4 flow table in units of 256K entries.
NOTE:
Prior to Junos OS Release 16.1R1 and 15.1F2, any changes in the
configured size of the flow table initiates an automatic reboot of the FPC,
and we recommend that you run this command in a maintenance window.
Starting with Junos OS Release 16.1R1 and 15.1F2, by default, the software allocates 1K
entries for IPv4 flow tables. To allocate fifteen 256K IPv4 flow tables, the former default,
you can enter this configuration from the
[edit]
user@router# set chassis fpc inline-services flow-table-size

ipv4-flow-table-size 15

—Number of 256K flow entries available for the IPv4 flow table.
units
Range: 1 through 15
Default: 1024 (1K)—Starting with Junos OS Release 16.1R1 and 15.1F2
Default: 3,932,160 (3840K)—Prior to Junos OS Release 16.1R1 and 15.1F2
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Release
Description
16.1R1
Starting with Junos OS Release 16.1R1 and 15.1F2, by default, the software
allocates 1K entries for IPv4 flow tables.
Configuring Inline Active Flow Monitoring on page 15
hierarchy level:
[edit]
Copyright © 2017, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

Table of Contents