Excessive Temperature Or Humidity - Canon iPF6300 User Manual

Hide thumbs Also See for iPF6300:
Table of Contents

Advertisement

Cause
Direct sunlight or strong lighting may be
shining on the printer and causing the sensor
to malfunction.

Excessive temperature or humidity.

Cause
The temperature or humidity
where the printer is installed is out
of the acceptable range for opera-
tion.
Before borderless printing, move the blue platen switch.
Cause
The blue Switch on the platen was set to the side
opposite ● when a borderless print job was re-
ceived.
Blue platen switch is dirty.
Cause
The blue Switch on the platen is dirty.
Move the blue platen switch No.xx to the right. (xx represents a number)
The printer has detected that the blue Switch on the
platen needed in maintenance during printing is set
away from the ● mark.
Cannot adjust paper feed.
Cause
The Printhead nozzles are clog-
ged.
iPF6300
Press the OK button to clear the error.
Take steps to ensure the printer is not used when exposed to direct
sunlight or strong lighting.
Press ▲ or ▼ to select Stop, and then press the OK button to stop printing.
Use the printer under suitable environmental conditions. Also note that vari-
ous environmental conditions are recommended for various types of paper.
For details on the recommended environmental conditions, see the Paper Ref-
erence Guide.
(See "Types of Paper.")
Press ▲ or ▼ to select Continue, and then press the OK button to continue
with color calibration. However, note that correct adjustment may not be pos-
sible.
Open the Top Cover and clean the blue Switch on the platen.
(See "Cleaning Inside the Top Cover.")
Cause
Execute Adj. Quality again, as follows.
1.
Press the OK button to clear the error.
2.
Print a test pattern to check the nozzles.
(See "Checking for Nozzle Clogging.")
Error Message
>
Messages regarding printing or adjustment
Corrective Action
Corrective Action
→P.665
Corrective Action
Before borderless printing, set the blue Switch on the platen to
the ● side.
(See "Setting the Blue Switch on the Platen.")
Corrective Action
Corrective Action
Set blue platen Switch of the indicated number toward the
● side.
(See "Setting the Blue Switch on the Platen.")
→P.895
Corrective Action
→P.847
Excessive temperature or humidity.
→P.895
→P.864
>
12