PROBLEM
Little or no solution flow to the
floor
No power to machine
Little or no propel
CAUSE
Solution tank empty
Solution flow turned off or
set too low
Solution strainer plugged
Solution hoses obstructed
Solution solenoid valve
obstructed or stuck
Vent hole in solution tank
lid obstructed
Battery disconnected
Emergency shut-off
activated
Battery connections
corroded
Faulty main contactor
Faulty key switch
Low battery charge
Machine turned on with
control handle not in
neutral
Wheels spin
Controller overheated
Loose connection
STRIDE2 36V (SS) 98745 11/08/99
MACHINE TROUBLESHOOTING
SOLUTION
Fill solution tank
Turn on or increase flow
setting
Clean solution strainer
Clear obstruction from
hose
Clean or replace
Clear obstruction from vent
hole
Check all battery cable
connections
Reset
Clean connections
Replace contactor
Replace switch
Charge batteries
Allow control handle to
return to neutral. Restart
Decrease brush pressure
Allow cool down period
Check motor wires and
connection