1. SOLUTION CONTROL KNOB
Controls solution flow to scrub deck.
To increase flow, rotate knob clockwise.
To decrease flow, rotate knob
counterclockwise.
If the brush motors are turned off or the
direction control lever is in neutral, the flow is
automatically interrupted until the motors are
turned on again. This feature prevents
unintentional draining of the solution tank and
allows the operator to adjust the solution flow
to the scrub deck without resetting each time
the scrubbing operation is interrupted.
2. BRUSH SWITCH
Controls the scrub brush motors.
To turn scrub brushes on, press the top of the
switch. The brushes will not rotate with the
direction control lever in neutral.
To turn scrub brushes off, press the bottom of
the switch.
3. BRUSH PRESSURE SWITCH
Adjusts the amount of brush pressure to the
floor by raising or lowering the scrub deck.
To increase brush pressure, press the bottom
of the switch.
To decrease brush pressure or raise the scrub
deck, press the top of the switch.
4. BRUSH PRESSURE INDICATOR
The brush pressure indicator corresponds to
the amp draw of the scrub brush motors to tell
how hard the motors are working. The green
zone indicates proper operating brush
pressure. The red zone indicates excessive
brush pressure. Operating in the red zone will
cause the brush circuit breakers to trip.
5. VACUUM SWITCH
6. SQUEEGEE LIFT LEVER
7. RECOVERY TANK FULL INDICATOR
8. KEY SWITCH
STRIDE2 36V (SS) 98745 11/08/99
Controls the vacuum motor.
To start vacuum motor, press the top of the
switch. The vacuum motor will not operate
with the recovery tank full indicator light on.
To stop vacuum motor, press the bottom of
the switch.
Raises and lowers the squeegee.
To lower the squeegee, lift the lever from its
raised position.
To raise the squeegee, lift the lever from its
lowered position.
Will light when the float switch indicates a full
recovery tank. The vacuum motor will not
operate with recovery tank full. The recovery
tank must be drained and the vacuum switch
or key switch turned off before the indicator
light will turn off.
Controls the power for machine functions.
To turn machine on, rotate key clockwise.
To turn machine off, rotate key
counterclockwise.
FOR SAFETY: Always remove the key
when machine is unattended or during
service to prevent unauthorized
movement.