Low Alternator 2 Output; Original Issue - Cirrus SR22 Pilot Operating Handbook

Aircraft serials 22-3915 & subsequent 3600 pound takeoff weight
Table of Contents

Advertisement

Section 3A
Abnormal Procedures

Low Alternator 2 Output

ALT 2 Caution (Failure)
1. ALT 2 Circuit Breaker .............................................. CHECK & SET
2. ALT 2 Master Switch ........................................................... CYCLE
If alternator does not reset (low A2 Current and M2 voltage less
than M1 voltage):
3. ALT 2 Master Switch ................................................................OFF
4. Continue Flight, avoiding IMC or night flight as able (reduced
power redundancy).
Amplification
Alternator 2 output is low, indicative of alternator failure; isolated Alt 2
failure will not typically be associated with any other unusual
indications, cautions or warnings (Alt 1 will pick up all loads).
3A-14
ALT 2
Cirrus Design
SR22
P/N 13772-004

Original Issue