Sharp AL-1611 Service Manual page 44

Digital copier
Hide thumbs Also See for AL-1611:
Table of Contents

Advertisement

Main
Sub
Contents
code
code
26
1
Option switch display
<Not Used>
3
Auditor setting
5
Counter mode setting
6
Destination setting
Details of operation
Used to display the installed option on the operation panel. (The LED corre-
sponding to the installed option is lighted.)
Key operation
Display select:
<Lighting with an option installed>
When "A" is displayed:
Magnification
Shifter: Paper empty LED
ratio display key
Job separator: JAM LED
SPF: SPF select LED
RSPF: SPF JAM LED
Duplex mode: Main cassette select LED
Simplex mode: Multi manual paper feed select LED
MCU JMPER1: Top of the magnification ratio display
MCU JMPER2: 2nd of the magnification ratio display
MCU JMPER3: 3rd of the magnification ratio display
MCU JMPER7: 4th of the magnification ratio display
MCU JMPER7: 5th of the magnification ratio display
MCU JMPER7: 6th of the magnification ratio display
MCU JMPER7: 7th of the magnification ratio display
MCU JMPER8: Bottom of the magnification ratio display
When "b" is displayed:
Cassette (2nd step): No. 2 cassette select LED
Cassette (3rd step): No. 3 cassette select LED
Cassette (4th step): No. 4 cassette select LED
Memory installed: Paper empty LED
FAX: JAM LED
Printer: Main body JAM LED
ERDH: Main cassette select LED
16CPM: SPF JAM LED
20CPM: SPF select LED
Document sensor: Auto paper select LED
Used to display the current auditor setting with the numbers at right. After
entering the set value, press the start key, and the set value is stored.
Key operation/Display
0: Built-in auditor
1: Coin vendor
2: Others
Used to set the print counter mode in A3.
Used to display the currently set counter value with the numbers at right. After
entering the set value, press the start key, and the set value is stored.
Key operation/Display
0: Total/Developer = 2 counts
1: Total/Developer = 1 count
2: Total/Developer = 2 counts
3: Total/Developer = 1 count
Used to display the current destination setting with the numbers at right.
After entering the set value, press the start key, and the set value is stored.
Key operation/Display
0: Japan
1: USA (Inch series)
2: Canada (Inch series)
3: Germany 1 (AB series)
4: UK (AB series)
5: Not used
6: France (AB series)
7: EX inch series
AL-1611/AL-1622 SIMULATIONS
8 – 7
Display
Maintenance = 2 counts
Maintenance = 2 counts
Maintenance = 1 count
Maintenance = 1 count
8: X AB series
9: X inch series (FC conformity)
10: EX AB series (FC conformity)
(Australia, Newzealand)
11: China (AB series)
12: Taiwan (AB series)
13: Germany 2 (AB series)
Initial
Set range
value
0
0 ~ 2
0
0 ~ 3
8
0 ~ 13

Advertisement