For The Installer; About The Box; Indoor Unit; To Remove The Accessories From The Indoor Unit - Daikin FCAG35AVEB Installation And Operation Manual

Split system air conditioners
Hide thumbs Also See for FCAG35AVEB:
Table of Contents

Advertisement

2 About the box

Technical engineering data
▪ A subset of the latest technical data is available on the regional
Daikin website (publicly accessible).

For the installer

2
About the box
2.1

Indoor unit

2.1.1
To remove the accessories from the
indoor unit
a
b
c
h
i
l
a
Paper pattern for installation (upper part of packing)
b
General safety precautions
c
Indoor unit installation and operation manual
d
Installation guide
e
Washers for hanger brackets
f
Screws (to temporarily attach the paper pattern for
installation to the indoor unit)
g
Cable ties
h
Metal clamp
i
Insulation piece (drain pipe)
j
Sealing pads: Large (drain pipe), medium 1 (gas pipe),
medium 2 (liquid pipe), small (electrical wiring)
k
Drain hose
l
Insulation piece: Small (liquid pipe)
m
Insulation piece: Large (gas pipe)
3

About the units and options

3.1

About the indoor unit

Use the system in the following temperature and humidity ranges for
safe and effective operation.
For combination with R410A outdoor unit, refer to the following table:
Outdoor units
RR71~125
Outdoor
–15~46°C DB
temperature
Indoor
18~37°C DB
temperature
12~28°C WB
RQ71~125
Outdoor
–5~46°C DB
temperature
Indoor
18~37°C DB
temperature
12~28°C WB
Installation and operation manual
4
▪ The full set of latest technical data is available on the Daikin
RXS35~60
3MXS40~68
4MXS68~80
d
e
f
g
5MXS90
RZQG71~140
j
k
RZQSG71~140
m
RZQ200~250
AZQS71~125
For combination with R32 outdoor unit, refer to the following table:
RXM35~60
3MXM40~68
4MXM68~80
5MXM90
RZAG71~140
Cooling
Heating
RZASG71~140
–9~21°C DB
–10~15°C WB
10~27°C DB
extranet (authentication required).
Outdoor units
Cooling
Outdoor
–10~46°C DB
temperature
Indoor
18~32°C DB
temperature
Outdoor
–10~46°C DB
temperature
Indoor
18~32°C DB
temperature
Outdoor
–15~50°C DB
temperature
Indoor
18~37°C DB
temperature
12~28°C WB
Outdoor
–15~46°C DB
temperature
Indoor
20~37°C DB
temperature
14~28°C WB
Outdoor
–5~46°C DB
temperature
Indoor
20~37°C DB
temperature
14~28°C WB
Outdoor
–15~46°C DB
temperature
Indoor
20~37°C DB
temperature
14~28°C WB
Outdoor units
Cooling
Outdoor
–10~46°C DB
temperature
Indoor
18~32°C DB
temperature
Outdoor
–10~46°C DB
temperature
Indoor
18~32°C DB
temperature
Outdoor
–20~52°C DB
temperature
Indoor
18~37°C DB
temperature
12~28°C WB
Outdoor
–15~46°C DB
temperature
Indoor
20~37°C DB
temperature
14~28°C WB
Heating
–15~24°C DB
–16~18°C WB
10~30°C DB
–15~24°C DB
–16~18°C WB
10~30°C DB
–19~21°C DB
–20~15.5°C WB
10~27°C DB
–14~21°C DB
–15~15.5°C WB
10~27°C DB
–14~21°C DB
–15~15°C WB
10~27°C DB
–14~21°C DB
–15~15.5°C WB
10~27°C DB
Heating
–15~24°C DB
–16~18°C WB
10~30°C DB
–15~24°C DB
–16~18°C WB
10~30°C DB
–19.5~21°C DB
–20~15.5°C WB
10~27°C DB
–14~21°C DB
–15~15.5°C WB
10~27°C DB
FCAG35~140AVEB
Split system air conditioners
4P471224-1 – 2017.03