Operating The System; About Operating The System; About Cooling, Heating, Fan Only, And Automatic Operation; About The Heating Operation - Daikin FCAG35AVEB Installation And Operation Manual

Split system air conditioners
Hide thumbs Also See for FCAG35AVEB:
Table of Contents

Advertisement

Outdoor units
3MXM40~68
Outdoor
–10~46°C DB
temperature
4MXM68~80
Indoor
18~32°C DB
5MXM90
temperature
RZAG71~140
Outdoor
–20~52°C DB
temperature
Indoor
18~37°C DB
temperature
12~28°C WB
RZASG71~140
Outdoor
–15~46°C DB
temperature
Indoor
20~37°C DB
temperature
14~28°C WB
AZAS71~140
Outdoor
–15~46°C DB
temperature
Indoor
20~37°C DB
temperature
14~28°C WB
Indoor humidity
(a)
To avoid condensation and water dripping out of the unit. If
the temperature or the humidity is beyond these conditions,
safety devices may be put in action and the air conditioner
may not operate.
11.2

Operating the system

11.2.1

About operating the system

▪ To protect the unit, turn on the main power switch 6 hours before
operation.
▪ If the main power supply is turned off during operation, operation
will restart automatically after the power turns back on again.
11.2.2
About cooling, heating, fan only, and
automatic operation
▪ The air flow rate may adjust itself depending on the room
temperature or the fan may stop immediately. This is not a
malfunction.
11.2.3

About the heating operation

It may take longer to reach the set temperature for general heating
operation than for cooling operation.
The following operation is performed in order to prevent the heating
capacity from dropping or cold air from blowing.
Defrost operation
In heating operation, freezing of the outdoor unit's air cooled coil
increases over time, restricting the energy transfer to the outdoor
unit's coil. Heating capability decreases and the system needs to go
into defrost operation to be able to deliver enough heat to the indoor
units.
The indoor unit will stop fan operation, the refrigerant cycle will
reverse and energy from inside the building will be used to defrost
the outdoor unit coil.
The indoor unit will indicate defrost operation on the display
Hot start
In order to prevent cold air from blowing out of an indoor unit at the
start of heating operation, the indoor fan is automatically stopped.
The display of the user interface shows
time before the fan starts. This is not a malfunction.
FCAG35~140AVEB
Split system air conditioners
4P471224-1 – 2017.03
11.2.4
Cooling
Heating
–15~24°C DB
1 Press the operation mode selector button on the user interface
–16~18°C WB
10~30°C DB
–19.5~21°C DB
–20~15.5°C WB
10~27°C DB
2 Press the ON/OFF button on the user interface.
Result: The operation lamp lights up and the system starts
operating.
–14~21°C DB
–15~15.5°C WB
11.3
10~27°C DB
11.3.1
–14~21°C DB
▪ The function of this program is to decrease the humidity in your
–15~15.5°C WB
10~27°C DB
▪ The micro computer automatically determines temperature and
(a)
≤80%
▪ The system does not go into operation if the room temperature is
11.3.2
To start
1 Press the operation mode selector button on the user interface
2 Press the ON/OFF button of the user interface.
To stop
3 Press the ON/OFF button on the user interface once again.
Result: The operation lamp goes out and the system stops
operating.
11.4
Refer to the operation manual of the user interface.
11.4.1
For the following conditions, a micro computer controls the air flow
direction which may be different from the display.
▪ When the room temperature is
.
▪ When operating continuously at horizontal air flow direction.
▪ When continuous operation with downward air flow is performed
. It may take some
The air flow direction can be adjusted in one of the following ways:

To operate the system

several times and select the operation mode of your choice.
Cooling operation
Heating operation
Fan only operation

Using the dry program

About the dry program

room with minimal temperature decrease (minimal room cooling).
fan speed (cannot be set by the user interface).
low (<20°C).

To use the dry program

several times and select
(program dry operation).
Result: The operation lamp lights up and the system starts
operating.
NOTICE
Do not turn off power immediately after the unit stops, but
wait for at least 5 minutes.

Adjusting the air flow direction

About the air flow flap

Double flow+multi-flow units
Cooling
▪ When starting operation.
lower
than
the
set
▪ When the room temperature is
temperature.
higher
temperature.
▪ At defrost operation.
at the time of cooling with a ceiling-suspended or a wall-mounted
unit, the micro computer may control the flow direction, and then
the user interface indication will also change.
Installation and operation manual
11 Operation
Heating
than
the
set
15