Parameter list
Parameter
Function
Analog input
73
selection
Terminal 4 input
267
selection
Input filter time
74
constant
Reset selection/
disconnected PU
75
detection/PU stop
selection
Parameter write
77
selection
Reverse rotation
78
prevention
selection
Operation mode
79
selection
Communication
startup mode
340
selection
80
Motor capacity
Number of motor
81
poles
Speed control
gain (Advanced
89
magnetic flux
vector)
Control method
800
selection
82
Incre-
Initial
Name
ments
Value
1
1
1
0
1
1
1
14
1
0
1
0
1
0
1
0
0.01kW
9999
1
9999
0.1%
9999
1
20
Range
Description
Terminal 2 input
0
0 to 10V
1
0 to 5V
10
0 to 10V
11
0 to 5V
0
Terminal 4 input 4 to 20mA
1
Terminal 4 input 0 to 5V
2
Terminal 4 input 0 to 10V
Primary delay filter time constant for the
0 to 8
analog input. A larger setting results in a
larger filter.
You can select the reset input acceptance,
disconnected PU (FR-PU04/FR-PU07)
connector detection function and PU stop
0 to 3,
function.
14 to 17
For the initial value, reset always enabled,
without disconnected PU detection, and
with PU stop function are set.
0
Write is enabled only during a stop
1
Write disabled.
Write is enabled in any operation mode
2
regardless of operation status.
0
Both forward and reverse rotations allowed
1
Reverse rotation disabled
2
Forward rotation disabled
0
External/PU switchover mode
1
Fixed to PU operation mode
2
Fixed to External operation mode
3
External/PU combined operation mode 1
4
External/PU combined operation mode 2
6
Switchover mode
External operation mode (PU operation
7
interlock)
0
As set in Pr. 79.
1
Started in Network operation mode.
Started in Network operation mode.
Operation mode can be changed between
10
the PU operation mode and Network
operation mode from the operation panel.
0.1 to 15kW Applied motor capacity.
9999
V/F control
2, 4, 6, 8, 10 Set the number of motor poles.
9999
V/F control
Motor speed fluctuation due to load
fluctuation is adjusted during Advanced
0 to 200%
magnetic flux vector control.
100% is a referenced value.
9999
Gain matching with the motor set in Pr. 71.
Advanced magnetic
20
flux vector control
General-purpose
30
magnetic flux vector
control
Param
Param
eter
eter
Copy
Clear
Polarity reversible
Not used
With
When a value other
than "9999" is set in
Pr. 80 and Pr. 81.
All
Param
eter
Clear
×
×
×
×
×