Parameter list
Parameter
Function
DU/PU main
52
display data
selection
FM terminal
54
function selection
Watt-hour meter
170
clear
Operation hour
171
meter clear
Monitor decimal
268
digits selection
Energization time
carrying-over
563
times
Operating time
carrying-over
564
times
78
Incre-
Initial
Name
ments
Value
1
0
1
1
1
9999
1
9999
1
9999
1
0
1
0
Range
Description
Select monitor to be displayed on the
operation panel and parameter unit and
monitor to be output to the terminal FM.
0: Output frequency (Pr.52)
0, 5, 7 to
1: Output frequency (Pr.54)
12, 14, 20,
2: Output current (Pr.54)
23 to 25,
3: Output voltage (Pr.54)
52 to 57,
5: Frequency setting value
61, 62, 100
7: Motor torque
8: Converter output voltage
9: Regenerative brake duty
10: Electronic thermal relay function load
factor
11: Output current peak value
12: Converter output voltage peak value
14: Output power
20: Cumulative energization time (Pr. 52)
21: Reference voltage output (Pr. 54)
23: Actual operation time (Pr. 52)
24: Motor load factor
1 to 3, 5,
25: Cumulative power (Pr. 52)
7 to 12,
52: PID set point
14, 21,
53: PID measured value
24, 52, 53,
54: PID deviation (Pr. 52)
61, 62
55: I/O terminal status (Pr. 52)
56: Option input terminal status (Pr. 52)
57: Option output terminal status (Pr. 52)
61: Motor thermal load factor
62: Inverter thermal load factor
100: Set frequency is displayed during a
stop and output frequency is
displayed during operation (Pr. 52)
Set "0" to clear the watt-hour meter
0
monitor.
Set the maximum value when monitoring
10
from communication to 0 to 9999kWh.
Set the maximum value when monitoring
9999
from communication to 0 to 65535kWh.
Set "0" to clear the operation time monitor.
0, 9999
Setting "9999" does not clear.
0
Displayed as integral value
1
Displayed in 0.1 increments.
9999
No function
The numbers of cumulative energization
(0 to
time monitor exceeded 65535h is
65535)
displayed. (Reading only)
The numbers of operation time monitor
(0 to
exceeded 65535h is displayed.
65535)
(Reading only)
All
Param
Param
Param
eter
eter
eter
Copy
Clear
Clear
×
×
×
×
×
×
×
×
×
×