Mitsubishi Electric FR-E700 Basic Instruction Manual page 102

Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Parameter
Function
Name
Remote output
495
selection
Remote output
496
data 1
Remote output
497
data 2
502
Refer to Pr.124.
——
503
Maintenance timer
Maintenance timer
504
alarm output set
time
USB
547
communication
station number
USB
communication
548
check time
interval
Refer to Pr.338 and Pr.339.
551
549
Refer to Pr.117 to Pr.124.
——
550, 551
Refer to Pr.338 and Pr.339.
Current average
555
time
Data output mask
556
time
Current average
value monitor
557
signal output
reference current
563, 564
Refer to Pr.52.
571
Refer to Pr.13.
——
611
Refer to Pr.57.
Speed smoothing
653
control
665
Refer to Pr.882.
——
Incre-
Initial
Range
ments
Value
Remote output data
0
clear at powering OFF Remote output data
Remote output data
1
retention at powering
OFF
1
0
Remote output data
10
clear at powering OFF Remote output data
Remote output data
11
retention at powering
OFF
1
0
0 to 4095
Output terminal can be switched ON and
OFF.
1
0
0 to 4095
Displays the cumulative energization time
of the inverter in 100h increments.
1
0
0(1 to 9998)
(Reading only)
Writing the setting of "0" clears the
cumulative energization time.
Time taken until when the maintenance
0 to 9998
timer alarm output signal (Y95) is output.
1
9999
9999
No function
1
0
0 to 31
Inverter station number.
USB communication is enabled.
However, the inverter will trip (E. USB) if
0
operation is changed to PU operation
0.1s
9999
mode.
0.1 to
Interval of communication check time.
999.8s
9999
No communication check
Time taken to average the current during
0.1s
1s
0.1 to 1.0s
start bit output (1s).
Time for not obtaining (mask) transient
0.1s
0s
0 to 20s
state data.
Rated
Reference (100%) for outputting the signal
0.01A
inverter
0 to 500A
of the current average value.
current
The torque fluctuation is reduced to reduce
0.1%
0
0 to 200%
vibration due to mechanical resonance.
Parameter list
Param
Description
eter
Copy
clear at inverter
reset
retention at inverter
reset
×
×
×
All
Param
Param
eter
eter
Clear
Clear
×
×
×
×
×
×
×
3
93