3. Disassembly & Reassembly
3-1 Overall Disassembly & Reassembly
Notice
- Be sure to separate the power cord before disassembling the unit.
- Discharge the capacitors first when separating PCB's with high capacity capacitors such as SMPS, X Main Board, Y Main
Board, etc. (A spark may be generated by the electric charge, and there is danger of electronic shock.)
- Check that the cables are properly connected referring to the circuit diagram when disassembling or assembling the unit
taking care not to damage the cables.
- Take care not to scratch the Glass Filter in the front.
- Assemble the boards in the reverse order of the disassembly.
- The plasma must be layed down on a flat padded surface for disassembly and reassembly.
3-1-1 Separation of ASSY STAND P-BASE
Part Name
① Remove 4 screws.
Stand
: PH,+,WSP,S,M4,L35,ZPC(BLK)
② Pull the stand down to remove it from
the unit.
Please lay the PDP unit face down on a
soft surface when removing the stand.
3-1-2 Separation of ASSY BRACKET P-TERMINAL
Part Name
① Remove the 8 screws on the Bracket
Bracket
Terminal
Terminal. (
: WSP,PH,+,M4,L8,ZPC(YEL),SWRCH1
② Remove the 8 Hex nuts for the PC
input. (
)
: M3,L6,NI PLT,SUM24L,#4-40
③ Remove Bracket Terminal.
④ Remove the 2 screws on the Bracket
Terminal. (
: BH,+,-,M3,L8,ZPC(BLK)