Siemens sinumerik 840D sl Function Manual page 525

Hide thumbs Also See for sinumerik 840D sl:
Table of Contents

Advertisement

Detailed description
2.5 Startup
2.5
Startup
Compile cycle
Before starting up the technological function, make sure that the corresponding compile
cycle has been loaded and activated.
References:
FB3/ Function Manual, Special Functions, Installation of Compile Cycles (TE01)
/HBI/SINUMERIK 840Di Manual, NC Installation and Start-Up with HMI Advanced, Loadable
Compile Cycles chapter
2.5.1
Activating the technological function
The technological function is activated via the machine data:
MD60940 $MN_CC_ACTIVE_IN_CHAN_CLC[0], bit n = 1
n = channel number - 1; bit0 = channel 1, bit1 = channel 2, etc.
Note
The technological function can be activated for several channels simultaneously.
2.5.2
Configuring the memory
Memory configuration
The technological function requires additional data in the NCK-internal block memory. The
following memory-configuring channel-specific machine data must be parameterized:
• MD28090 $MC_MM_NUM_CC_BLOCK_ELEMENTS = x + 4
• MD28100 $MN_MM_NUM_CC_BLOCK_USER_MEM = x + 20
• 1) See note
Note
The values indicated must be entered in addition to the existing machine data value x.
20
for compile cycles)
compile cycles (DRAM) in kBytes)
(number of block elements
1)
(size of block memory for
1)
Special functions: Clearance Control (TE1)
Function Manual, 11/2006, 6FC5397-2BP10-2BA0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents