1.4.2 Clearing the Interface Statistics

You can run the reset command to clear interface statistics before recollecting traffic statistics
on the interface.
Context
The interface statistics cannot be restored after you run the reset command to clear it. So, confirm
the action before you use the command.
To reset the interface statistics of those displayed by running the display interface command,
run the following commands in the user view. Clear the interface statistics before collecting the
traffic.
Procedure
l
----End

1.5 Configuration Examples

This section describes details about POS interfaces, including applicable scenarios and
configuration commands.
1.5.1 Example for Directly Connecting Devices Through POS
Interfaces
This example shows how to connect two devices through POS interfaces in typical networking.
Networking Requirements
As shown in
a pair of single-mode fibers for receiving and sending packets; HDLC is the link layer protocol.
It is required that Switch A and Switch B can communicate.
Figure 1-2 Networking diagram of connecting devices directly through POS interfaces
Switch A
Issue 02 (2011-07-15)
CAUTION
Run the reset counters interface [ interface-type [ interface-number ] ] command to clear
the interface statistics displayed by running the display interface command.
Figure
1-2, POS interfaces on Switch A and Switch B are directly connected with
POS1/0/0
10.1.1.1/30
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
POS1/0/0
Switch B
10.1.1.2/30
1 POS Interface Configuration