Standard Features - Graco ProMix 2KS Repair Manual

Plural component proportioner
Hide thumbs Also See for ProMix 2KS:
Table of Contents

Advertisement

Hazardous Location Approval
Models using a G250 or G250HR for both A and B meters are approved for installation in a Hazardous Location -
Class I, Div I, Group D, T3 or Zone I Group IIA T3.
Maximum Working Pressure
Maximum working pressure rating for RoboMix Fluid Station Systems is 190 psi (1.31 MPa, 13.1 bar).
See the identification label on your EasyKey or RoboMix fluid station for the maximum working pressure.
See F
. 2.
IG
ProMix RoboMix Systems Maximum Working Pressure
RoboMix Panel Options (all) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 psi (1.31 MPa, 13.1 bar)
Flow Meter Fluid Flow Rate Range
G250 Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75-3800 cc/min. (0.02-1.0 gal./min.)
G250HR Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-1900 cc/min. (0.01-0.50 gal./min.)

Standard Features

Feature
EasyKey with LCD
Fiber Optic and Power Cables, 50 ft (15.25 m)
Remote Fluid Station, 25 cc Integrator
Discrete I/O Board
A Side Dump Valve, if color valve(s) selected
B Side Dump Valve, if catalyst valve(s) selected
Flow Control with 15 ft (4.57 m) Cable (if selected)
Basic Web Interface
312780K
System Configuration and Part Numbers
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents