Servicing Fluid Manifold

Removal
1. Follow Servicing Flow Meters Mounted on Wall
Panel, Removal steps 1-5, page 50.
2. Disconnect air and fluid lines from the manifold (4).
3. Holding onto the fluid manifold (4), loosen the three
screws (341) holding the bracket (325) to the fluid
station. Lift the fluid manifold (4) and pull it away
from the panel. Service as instructed in the Fluid
Mix Manifold manual 312781.
Installation
1. Secure the fluid manifold (4) and mounting plate
(325) with three screws (341).
2. Install meters. See Installation steps 1-3, page 50.
3. Connect air and fluid lines.
4. Calibrate meters as instructed in ProMix Operation
manual.
312780K
341
F
. 25: Fluid Manifold
IG
Servicing Color Change Module,
Color/Catalyst Valves, and
Dump Valves
1. Follow Before Servicing, page 40.
2. See manual 312787 for the color change module.
3. See manual 312783 for the color/catalyst valve
stacks.
4. See manual 312786 for the dump valve kits.
5. See manual 312782 to service an individual valve.
Service
325
4
TI12654a
51