Servicing Flow Meters Mounted On Wall Panel - Graco ProMix 2KS Repair Manual

Plural component proportioner
Hide thumbs Also See for ProMix 2KS:
Table of Contents

Advertisement

Service
Servicing Flow Meters Mounted
on Wall Panel
Coriolis Meter
1. Follow Before Servicing, page 40.
2. To remove and service the Coriolis meter, see man-
ual 313599.
G3000, G3000HR, or G3000A Meter
Removal
1. Follow Before Servicing, page 40.
2. Unscrew cable connector (CC) from meter (M). F
23.
3. Unscrew four 1/4-20 screws (MS) holding the meter
mounting plate (MP). F
4. Unscrew fluid line from meter inlet (P).
5. Unscrew meter (M) from dose valve connector (H).
F
. 23.
IG
6. Service meter as instructed in the meter manual
308778.
Installation
1. Screw meter (M) securely onto the dose valve con-
nector (H), using a wrench.
NOTE: To avoid leakage, secure the meter (M) to the
dose valve connector (H) before connecting it to the fluid
station.
Cable
17C743
17C909
F
. 24: Meter Cable Schematic
IG
50
. 23.
IG
Length
5 ft (1.52 m)
16 in. (406 mm)
2. Secure meter (M) and plate (MP) to fluid station with
screws (MS).
NOTE: You must assemble the meter sensor to the
meter body before connecting the cable to the sensor
for the meter to function properly.
3. Connect meter cable (CC). See F
4. Connect fluid line (P).
5. Calibrate meter as instructed in ProMix Operation
manual.
MS
P
.
IG
M
CC
F
. 23: G3000/G3000HR/G3000A Flow Meters
IG
1
2
3
J3
*
4
5
6
1
2
3
J12
*
4
5
6
GROUND
TERMINAL
*Connectors on Fluid Station Control Board
. 23.
IG
3X CABLE
PWR (RED)
COM (BLACK)
SIG (WHITE)
SHIELD/GRN
PWR (RED)
COM (BLACK)
SIG (WHITE)
SHIELD/GRN
PWR (RED)
COM (BLACK)
SIG (WHITE)
SHIELD/GRN
MP
H
TI12653a
FLOW METER A
FLOW METER B
FLOW METER SOLVENT
312780K