Sony MVS-6500 System Startup Manual page 27

Multi format switcher system with icp-6520/6530 control panel
Table of Contents

Advertisement

2
Set the tally generation reference.
New
Tally Enable menu
Enable
New menu
a Open the Engineering Setup >Router/Tally >Tally
Enable menu (7364).
b Check the tally settings for the program output.
If the settings of "OUT001" are as follows, you do
not need to change the settings. Proceed to step g.
Destination Level Tally Type Enable
Setting
OUT001
Value
c Press [New].
The New menu (7364.1) appears.
d Set each of the [Destination Address], [Destination
Level], and [Tally Type] parameters to "1".
e In the <Tally Enable> group, select [Enable].
f Press [Execute].
Tally settings for program output
Destination Address
Destination Level
Execute
Tally Type
1
R1
Enable
g In the Tally Enable menu (7364), check the tally
settings for the preview output.
If the settings of "OUT002" are as follows, you do
not need to change the settings. Proceed to step 3.
Destination Level Tally Type Enable
Setting
OUT002
Value
h Repeat steps c to f to make settings for the
preview output.
In step d, set the [Destination Address] parameter
to "2", [Destination Level] parameter to "1", and
[Tally Type] parameter to "2".
3
Set the serial tally output.
Serial Tally Port
Tally Group
Serial Tally menu
All Clear
Source Assign menu
a Open the Engineering Setup >Router/Tally >Serial
Tally menu (7367).
b In the <Serial Tally Port> group, select the target
port.
In this example, select [Panel Port].
1
G1
Enable
Source Assign
Tally Type
Serial Tally Port
Setting Tally
27