Sony DSR-1800 Service Manual page 197

Hide thumbs Also See for DSR-1800:
Table of Contents

Advertisement

3
3 HUMID (MOISTURE)
3
3
3
Checks the HUMID (condensation) sensor.
1. Execute the HUMID (MOISTURE).
2. Bring a cotton swab moistened with water in contact with the
HUMID sensor.
Confirm that [DRY] changes to [WET!] on the monitor
display.
3. Blow wind onto the HUMID sensor to evaporate any water.
Confirm that the display changes to [DRY] on the monitor 30
minutes later.
n
Once the HUMID sensor detects [WET!], even if make it dry
immediately, it takes 30 minutes to detect [DRY].
In the case of trouble :
If the display does not change from DRY to WET!, check whether
the HUMID sensor itself is defective.
Check also the HUMID sensor amplifier (DR-428 board).
DSR-1800/P/1600/P
HUMID (condensation) sensor
5-3. Contents of Maintenance Menu