M5 and M10 Internet Backbone Routers
M 5 a n d M 1 0 R o u t e r s P o w e r S u p p l y S p e c i f i c a t i o n s
Specification
Maximum power consumption
Input voltage
Input line frequency
Input current rating
Output voltages
Power and grounding cords and cables
M 5 a n d M 1 0 R o u t e r s L E D s
Component
PICs
Power supplies
Alarm LEDs
Red alarm
Yellow alarm
Red alarms occur when the router is started if no device is physically connected to the management fxp0 interface or if two power supplies are
physically installed but only one is switched on.
Ta k i n g C o m p o n e n t s O f f l i n e
Component
PIC
AC
434 W
100 through 264 VAC operating range
47 through 63 Hz, autoranging
8 A @ 100 VAC; 4 A @ 240 VAC
+1.5 V; +2.5 V; +3.3 V; +5 V; +12 V
Country-specific; see M5 and M10 Internet
Backbone Router Hardware Installation Guide
LED
1 LED per port, with 4 states: Red, Green, Amber, Off
Blue OUTPUT OK
Large circular red
Large triangular amber
Procedure
1. Press the PIC offline button, located on the PIC faceplate.
2. Press and hold the button until the PIC LED lights red (about 5 seconds).
3. Press and hold the offline button again after installing the replacement PIC to bring the PIC online.
DC
434 W
–42.5 through –72 VDC operating range
13.5 A @ –48 VDC (typical)
+1.5 V; +2.5 V; +3.3 V; +5 V; +12 V
12 AWG wire cables attaching to
quick-connect terminals; grounding
cable attaches to single-hole cable lug
Location
PIC faceplate
Power supply faceplate
Craft interface
Craft interface

Advertisement