: Starts a test. To start a test, you can also tap TEST on the
display.
Power key.
 
: Press
Connector for the ac adapter. The LED is red when the battery
charges, and green when the battery is fully charged. The LED
is yellow if the battery will not charge.
RJ45 connector: For functions available in future software
releases.
Micro-AB USB port: This USB port lets you connect the tester to
a PC so you can upload test results to the PC and install
software updates in the tester.
Type A USB port: This USB host port lets you save test results on
a USB flash drive or connect a video probe to the tester.
Headset jack.
PASS LED comes on when a test passes.
TEST LED comes on during a test.
FAIL LED comes on when a test fails.
TALK LED comes on when the talk function is on (see
adjust the volume, press
microphone.
TONE LED flashes and the toner comes on when you press
and a main tester is not connected to the remote.
LOW BATTERY LED comes on when the battery is low.
The LEDs also operate as a battery gauge when
you turn on the remote. See the Users Manual.
 
: Press
at the other end of the link. Press again to adjust the volume.
To turn off the talk function, hold down

How to Certify Twisted Pair Cabling

1. Power the Tester

Charge the battery if necessary. Connect the ac adapter to
ac power and to the adapter connector () shown in Figure
1. You can use the tester while the battery charges.

2. Select Settings

2-1 On the home screen, tap the test setup panel (see
Figure 2).
2-2 On the CHANGE TEST screen, tap a twisted pair test, then
tap EDIT.
to go to the home screen.
to use the headset to speak to the person
or the button on the headset's