General Operation

User Displays

When the system is operating, one of five displays may be shown. The display will
be turned off to conserve energy during normal operation. Pushing any button
will activate the display for approximately 20 seconds. While the display is active,
control status displays can be viewed, programming levels can be set as desired or
regeneration can be requested. During programming the display will be available
for approximately 5 minutes.
User 1
Typical user display. If volume is selected in Configuration Settings Step
4CS, shows volume remaining to regeneration. If volume is not selected in
Configuration Settings Step 4CS, this screen will not be shown. If a meter is not
used this display will not change.
User 2
Displays number of days to next regeneration.
User 3
Displays flow rate in gallons per minute. If a meter is not used this display will be
shown but 0 will be displayed.
This screen will not be shown if 7 day or 28 day is selected in Configuration
Settings Step 4CS. With 1.0T set in Configuration Settings Step 2CS, an "A" or
"B" will also be shown in this display to indicate the tank currently in Service.
User 4
Displays total flow in gallons since last reset. If a meter is not used this display
will be shown but 0 will be displayed. This screen will not be shown if 7 day or 28
day is selected in Configuration Settings Step 4CS.
PRESS  FOR 3 SECONDS TO RESET TO 0.
User 5
Shows current time.
Setting Time of Day
Push NEXT until time of day screen is displayed. Press and hold
 or  until the SET indicator is displayed, and the hour flashes.
Press  or  until the correct hour is displayed.
Then press NEXT. The minutes will flash. Press
 or  until the correct minute is displayed.
Press NEXT to return to the Display Screens. Time of day should
only need to be set after power outages lasting more than 8 hours,
if the battery has been depleted and a power outage occurs, or
when daylight saving time begins or ends. If a power outage
lasting more than 8 hours occurs, the time of day will flash on and
off which indicates the time of day should be reset. If a power
outage lasts less than 8 hours and the time of day flashes on and
off, the time of day should be reset and the battery replaced.