Icom IC-F5012 Service Manual page 18

Vhf mobile transceivers
Hide thumbs Also See for IC-F5012:
Table of Contents

Advertisement

M CONNECTION
Standard signal generator
–127 to –17 dBm
(0.1 V to 32 mV)
CAUTION:
DO NOT transmit while
SSG is connected to
the antenna connector.
to USB port
AC millivoltmeter
Audio generator
M ADJUSTMENT UTILITY SCREEN (example)
Click to open the
"I/O Check screen"
ADJ. CHANNEL
TX POWER
MOD. BALANCE
DEVIATION
CTCSS\DTCS
SQUELCH
REF. FREQUENCY
RX SENSITIVITY
LOCK VOLTAGE
RSSI
(S3 and S1 level)
Oscilloscope
Modulation analyzer
(DC measurable)
Attenuator
50 dB or 60 dB
PC
JIG CABLE
RF power meter
30 W [25 W ver.]
60 W [50 W ver.]
DC power supply
13.6 V / 20 A except [EUR]
13.2 V / 20 A [EUR]
to the MIC
connector
6 - 3
Frequency
counter
to the antenna connector
to DC cable