8.0

TEST PROCEDURES

8.1
Initial Functional check for PHILIPS 330
8.1.1
Insert the Test Production Card into the SIM reader at the back of the mobile phone and clip a charged
battery on the phone.
8.1.2
Press the "ON" button for 2 seconds at least and the LCD will show a message, which contains information
of FA (Final Adjustment) status and 12NC.
8.1.3
Follow the instructions as mentioned below:
Step
1
2
3
4
5
 PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Procedure
Press Key 1
Press Key 1 again.
Press key 2
Press key 2 again
Press key 3
(Audio loop local effect)
Press key 3 again
Press key 4
Press key 4 again
Press Key 5
(Checkerboard test) &
Backlight activation
Press Key 5 again
Service Repair Support
Observation
MANUAL TEST
GOOD
Left corner displays
BUZZER
TEST
Left corner displays
"LocalEffect"
" xx xx xx xx "
" xx xx "
Left corner displays
"KEY WITHOUT TEST"
Left corner displays
Checkerboard 1, 2 & 3 pixel on
Left corner displays
COMPANY RESTRICTED
VY-V-640-P330
Page : 12 of 43
Langue : EN
Date : 11/06/03
1
MANUAL
00 AUTOTEST
00 KBD RAM
2
MANUAL
01 AUTOTEST
00 KBD RAM
3
MANUAL
02 AUTOTEST
00 KBD RAM
4
MANUAL
03 AUTOTEST
00 KBD RAM
5
MANUAL
04 AUTOTEST
00 KBD RAM
VY-V-640-P330