Initial Functional Check for Fisio 620-CT3328 and Fisio 625-CT3329

Before to start the test procedure check the appearance of the humidity sticker located at the back of the phone.
Refer to CASES OUT OF WARRANTY GSM document to identify if the product is in/out of warranty.
8.1.1
Insert the Test Production Card into the SIM Reader at the back of the cellular phone and clip a charged
battery on the phone.
8.1.2
Press the «ON» button for 2 seconds at least and the LCD will show a message which contains information
of FA (Final Adjustment) status and 12NC.
8.1.3
Follow the instructions as mentioned below :
Step
Press Key 1
1
Press Key 1 again.
Press key 2
(Audio loop local effect)
2
Press key 2 again
Press key 3
Audio loop test (Speak to Mic
and listen echo from Speaker)
3
Press key 3 again
Press key 4
Check for the Backlight
function in the same time.
4
Press key 4 again
Press Key 5
(Checkerboard test)
5
Press Key 5 again
Press Key 6
(Inverted Checkerboard)
6
Press Key 6 again
 PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
PAGE SELECTION 00
Procedure
COMPANY RESTRICTED
Observation
Key without Test
Left corner displays 1
00
"LocalEffect"
" XX XX XX"
" XX XX"
Left corner displays 2
01
"AUDIO xx xx xx xx"
"EEP xx xx xxxx "
Left corner displays 3
02
Backlight must be on
Left corner displays 4
03
Checkerboard 1 pixel on
Left corner displays 5
04
Checkerboard 2 pixel on
Left corner displays
6
05
VY-V-640-620-3