8.2.7
GSM Specification (900 Mhz)
Test parameter
EMISSION
Phase Error RMS
Phase Error Peak
Frequency Error
Power Ramping
Modulation
Switching Transients
Timing Advance
Power Reading
Output Power Average
RECEPTION
Rx Level
Rx Qual
Rx Level
Rx Qual
Rx Level
Rx Qual
TCH LOOP
SENSITIVITY
BER
FER
BER
FER
If a phone is out of the specifications, it must be sent to the Repair Centre.
 PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
Channel
Level
1, 62, 124
5, 10, 15
1, 62, 124
5, 10, 15
1, 62, 124
5, 10, 15
1, 62, 124
5, 10, 15
1, 62, 124
5, 10, 15
1, 62, 124
5, 10, 15
1, 62, 124
5, 10, 15
1, 62, 124
Level 19
1, 62, 124
Level 15
1, 62, 124
Level 10
1, 62, 124
Level 5
1, 62, 124
-102 dBm
1, 62, 124
-85 dBm
1, 62, 124
-60 dBm
1, 62, 124
-85 dBm
1, 62, 124
-85 dBm
1, 62, 124
-102 dBm
1, 62, 124
-102 dBm
COMPANY RESTRICTED
VY-V-640-P330
Page : 18 of 43
Langue : EN
Date : 11/06/03
Standard specifications
0 to 5 degrees
-20 to +20 degrees
-90 Hz to +90 Hz
Mask
Mask
Mask
+/- 1.00 bit
5 +/- 5 dBm
13 +/- 3 dBm
23 +/- 2 dBm
33 +/- 2 dBm
4 to 12
0 to 1
21 to 29
0
46 to 54
0 to 0
0%
0%
< 2.44%
0%
VY-V-640-P330