lan2de.c03
Startup

Configuration for gatekeeper mode

3.2 Configuration for gatekeeper mode
Group 1
Optiset 100
HiPath HG
Hicom 150 E Office/
Hicom 150 H
Figure 3-1
The following stations must be differentiated from the user´s viewpoint:
Group 1: stations directly connected to the HICOM (Optisets, NoFe, CMI, ...),
stations registered at HiPath HG 1500 (C55 Opti clients, VCAPI clients)
and all trunk accesses.
Group 2: stations registered at the gatekeeper (H.323 standard clients such as
Netmeeting 3.01, HiNet LP5100, HiNet TA1100, etc.).
Note
In order to reach a port (station/line) of group 1, all stations of group 2 must dial an
additional code. This code is stripped for traffic in the direction to the HICOM by Hi-
Path HG 1500 (HLB2) and inserted for traffic in the reverse direction, i.e. stations of
group 1 do not dial the code.
The code must be set up in the RADVision gatekeeper NGK100 as a service and in
HiPath HG 1500 (HLB2) as a gateway prefix.
3-6
HXGM/HXGS
H.323 GK
Installation for gatekeeper mode
H.323 client
200
Group 2
LP5100
201
For internal use only
HFA client
300
LAN