Startup; Initial Startup Of Hipath Hg 1500; Initial Startup Via A Lan Port - Siemens HiPath HG 1500 Service Manual

Hicom 150 h; v 1.0
Hide thumbs Also See for HiPath HG 1500:
Table of Contents

Advertisement

For internal use only

3 Startup

3.1 Initial startup of HiPath HG 1500

Note
Windows 3.11 is no longer supported.

3.1.1 Initial startup via a LAN port

Prerequisites
The network card with the TCP/IP protocol must function correctly. The HiPath HG
1500 Assistant must be installed on the PC.
Step
1.
Configure the IP address of the PC (10.144.233.64) in the network
environment.
2.
Configure the gateway (10.144.233.63).
3.
From the DOS command window, ping the HiPath HG 1500
(IP 10.144.233.63).
4.
Generate an empty customer database and load to HiPath HG 1500.
5.
Save and administer customer data.
A31003-K5020-S100-4-7620