[Alarm information]
Error code
ST (assigned standby function) terminal
OFF
Undervoltage in main circuit
Retry in process
Frequency point setting error alarm
Clear command acceptable
Emergency stop command acceptable
Setting error alarm /
/
An error code and data are displayed
alternately twice each.
Display of first/last data items
/
DC braking
Flowing out of excess number of digits
Deceleration stop function during
power failure activated.
Auto-stop because of continuous
operation at the lower-limit frequency
Parameters in the process of
initialization
Points setting alarm 1
Points setting alarm 2
Note 1) When the DC braking (DB) function is assigned by using the input terminal function 22 or 23,
it is normal if "" disappears when opening the circuit between the terminal and CC (or P24).
13
Each message in the table is displayed to give a warning but does not cause the inverter to trip.
Name
The ST-CC (or P24) circuit is opened.
The supply voltage between R, S and T is
Internal communication fault.
The inverter is in process of retry.
A momentary stop occurred.
The frequency setting signals at points 1
This message is displayed when pressing
The operation panel is used to stop the
An error is found in a setting when data is
The first and last data item in the
DC braking in process
The number of digits such as frequencies
The slowdown stop prohibition function
The automatic stop function selected with
Parameters are being initialized to default
In case of pt=7, there are same setting
In case of pt=7, the inclination of V/f is
Description
under voltage.
The motor speed is being detected.
and 2 are set too close to each other.
the STOP key while an error code is
displayed.
operation in automatic control or remote
control mode.
reading or writing.
data group is displayed.
is more than 4.
(The upper digits have a priority.)
set with (momentary power
failure ride-through operation) is
activated.
was activated.
values.
value at least two on parameter vl,
f190, f192, f194, f196, or
f198 except 0.0Hz.
too high.
M-6
E6582175
Remedies
Close the ST-CC (or P24) circuit.
Measure the main circuit supply voltage.
If the voltage is at a normal level, the
inverter requires repairing for fault.
The inverter restarts automatically. Be
careful of the machine because it may
suddenly restart.
Set the frequency setting signals at points
1 and 2 apart from each other.
Press the STOP key again to clear the
trip.
Press the STOP key for an emergency
stop.
To cancel the emergency stop, press any
other key.
Check whether the setting is made
correctly.
Press MODE key to exit the data group.
The message goes off in several tens of
seconds if no problem occurs.
Note 1)
Lower the frequency free unit
magnification .
To restart operation, reset power supply or
input an operation signal again.
This function is cancelled, when
frequency reference reaches LL+0.2Hz or
operation command is OFF.
Normal if the message disappears after a
while (several seconds to several tens of
seconds).
Set the points to different values.
Set the inclination of V/f to be flat.