Toshiba Tosvert VF-S15 Instruction Manual page 115

Industrial inverter
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

Note1: The parameters set by communication option or RS485 communication are not searched and not
displayed.
Note2: The following parameters are not displayed in this auh, even if they are the most recent changes.
fc (Operation frequency of operation panel),
aul (Overload characteristic selection),
au2 (Torque boost setting macro function),
set (Checking the region setting),
f737 (All key operation prohibition ) ,
f739 (Password verification)
6.1.2
Application easy setting (aua)
aua : Application easy setting
Application easy setting (aua):
Parameters necessary to your machine can be set easily using the application easy setting.
The parameters necessary to the machine is set to easy setting mode parameters 1-32 (f751-f782). Set the
parameters using the easy setting mode. (Refer to section 4.5.)
[Parameter setting]
Title
Function
Application easy setting
aua
auf (Guidance function),
au1 (Automatic acceleration/deceleration),
typ (Default setting),
f700 (Parameter protection selection) ,
f738 (Password setting (f700)) ,
Adjustment range
0:-
1: Initial easy setting
2: Conveyor
3: Material handling
4: Hoisting
5: Fan
6: Pump
7:Compressor
F-3
E6582175
6
Default setting
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents