Compulsory Valve Operation Check Mode - Subaru LEGACY Service Manual

2004 year, engine section 1
Hide thumbs Also See for LEGACY:
Table of Contents

Advertisement

ENGINE (DIAGNOSTICS)
14.Compulsory Valve Operation
Check Mode
A: OPERATION
1) Prepare the Subaru Select Monitor kit. <Ref. to
EN(H4SO 2.5)(diag)-7, PREPARATION TOOL,
General Description.>
2) Connect the diagnosis cable to Subaru Select
Monitor.
3) Insert the cartridge to Subaru Select Monitor.
<Ref. to EN(H4SO 2.5)(diag)-7, PREPARATION
TOOL, General Description.>
4) Connect the test mode connector (A) located at
the lower portion of glove box.

Compulsory Valve Operation Check Mode

EN-00038
EN-00039
(A)
EN-02424
EN(H4SO 2.5)(diag)-42
5) Connect the Subaru Select Monitor to data link
connector located in the lower portion of instrument
panel (on the driver's side).
CAUTION:
Do not connect the scan tools except for Suba-
ru Select Monitor or OBD-II general scan tool.
6) Turn the ignition switch to ON (engine OFF) and
turn Subaru Select Monitor switch to ON.
(A) Power switch
7) On the «Main Menu» display screen, select the
{Each System Check} and press the [YES] key.
8) On the «System Selection Menu» display
screen, select the {Engine} and press the [YES]
key.
9) Press the [YES] key after the information of en-
gine type has been displayed.
10) On the «Engine Diagnosis» display screen, se-
lect the {System Operation Check Mode} and press
the [YES] key.
11) On the «System Operation Check Mode» dis-
play screen, select the {Actuator ON/OFF Opera-
tion} and press the [YES] key.
12) Select the desired compulsory actuator on the
«Actuator ON/OFF Operation» display screen and
press the [YES] key.
13) Pressing the [NO] key completes the compul-
sory valve operation check mode. The display will
then return to the «Actuator ON/OFF Operation»
screen.
EN-02533