Removal Of Heat Exchanger - Daikin ATXS35EV1B7 Service Manual

Inverter pair e-series
Hide thumbs Also See for ATXS35EV1B7:
Table of Contents

Advertisement

SiBE04-824
1.9
Removal of
Procedure
Step
1. Disconnecting the
refrigerant pipe
Remove the screws
1
which fix the heat
exchanger to the
installation plate.
Lift the indoor unit by a
2
wooden base.
Lift up the indoor unit
3
body slightly and pull
out the drain hose. (In
the case of left piping)
Disconnect the pipe
4
connection with 2 pair
of spanners.
Caution
From the point of view
of environmental
protection, be sure to
use a vacuum pump
for air purging.
Removal Procedure
Heat Exchanger
Warning
Be sure to turn off all power supplies at least 10 min. before
disassembling work.
Procedure
Indoor Unit
Points
Preparation
Remove the drain pan unit
according to the "Removal
of Drain Pan Unit."
Caution
In pump-down work, be sure
to stop the compressor
before disconnecting the
refrigerant pipe. If the
refrigerant pipe is
disconnected with the
compressor being operated
and the stop valve being
open, air may be sucked in to
generate an over-pressure in
refrigeration cycle, thus
resulting in pipe rupture or
accidental injury.
Place a plastic bag under
the drain pan to prevent
from wetting the floor with
remaining drain.
If the drain hose is
embedded in the wall,
disconnect the drain hose
beforehand.
Carry out the removal works
with 2 pair of spanners.
When the pipes are
disconnected, protect the
both openings of pipe side
and unit side from entering
of moisture.
163

Hide quick links:

Advertisement

Table of Contents
loading