Printed Circuit Board Connector Wiring Diagram
1.2.2 ARXS 50 E
Connectors
PCB(1)(Main PCB)
1)
2)
3)
4) S51,
5)
6)
7)
8) AC1,
9) HR1,
PCB(2)(Service Monitor PCB)
1) S52,
Note:
Other Designations
PCB(1)(Main PCB)
1)
2)
3) V2, V3,
PCB(2)(Service Monitor PCB)
1)
2)
3)
12
S10
Connector for terminal strip (indoor-outdoor transmission)
S20
Connector for electronic expansion valve coil
S40
Connector for overload protector
S101
Connector for service monitor PCB
S70
Connector for fan motor
S80
Connector for four way valve coil
S90
Connector for thermistors
(outdoor air, heat exchanger, and discharge pipe)
AC2
Connector for terminal strip (power supply)
HR2
Connector for reactor
S102
Connector for control PCB
FU1
Fuse
FU2, FU3
Fuse (3.15A)
V5, V6, V11 Varistor
LED A
Service monitor LED (green)
SW1
Forced operation ON/OFF switch
SW4
Field setting switch
Switch
Switch
Switch
(30A)
A: No function
B: For the changeover of the lower limit for cooling.
(OFF: –10°C, ON: –15°C)
Refer to page 46 for detail.
C: Powerful defrost operation (ON)
Printed Circuit Board Connector Wiring Diagram