INTRODUCTION
Congratulations on your purchase of the RMR132HG
Multi-Channel In-Out Thermo-Hygrometer with 433MHz cable
free sensor and radio-controlled calendar clock.
The basic package comes with a main unit, which is the
temperature and calendar clock station, and a remote unit, the
Thermo-Hygrometer sensor.
The main unit has large read-outs for indoors temperature and
humidity, calendar clock, temperatures and relative humidity
collected and transmitted by the remote unit. The main unit can
support up to
3
remote units.
The main unit is capable of keeping track of the maximum and
minimum recordings of different sites. And no wire installation is
required and the RMR132HG operates at 433MHz.
As for the calendar clock, it is radio-controlled. It automatically
synchronizes its current time and date when it is brought within an
approximate 1500km radius of the radio signal generated from
Frankfurt, Germany (DCF77).
You can also set the calendar clock manually when it is off range.
Other features include 4-language display, 4-step crescendo dual
alarms and interchangeable display modes.
1
RMR132HG_M_EN_R01
MAIN FEATURES
A
B
C
D
E
J
K
L
M
P
N
R
1
8/13/04, 12:30 PM
I
H
G
F
O
Q
S

Advertisement

Table of Contents
loading

Summary of Contents for Oregon Scientific RMR132HG

  • Page 1 Cable Free Sensor and RF Clock MODEL: RMR132HG USER MANUAL INTRODUCTION Congratulations on your purchase of the RMR132HG Multi-Channel In-Out Thermo-Hygrometer with 433MHz cable free sensor and radio-controlled calendar clock. The basic package comes with a main unit, which is the temperature and calendar clock station, and a remote unit, the Thermo-Hygrometer sensor.
  • Page 2 A. THREE-LINE LCD DISPLAY TEMPERATURE & RELATIVE HUMIDITY ALARM : K. [ L ] BUTTON Facilitates easy reading of remote and indoors temperature- humidity readings and calendar clock Sets the readings for the upper or lower temperature and B. [ ] BATTERY-LOW INDICATOR humidity of individual channels Activates when the remote-sensor or main unit battery power...
  • Page 3: Features: Remote Thermo-Hygro Sensor

    A. TWO-LINE LCD FEATURES: REMOTE Displays the current temperature and humidity monitored by THERMO-HYGRO SENSOR the remote unit B. LED INDICATOR Flashes when the remote unit transmits a reading ° ° F SLIDE SWITCH Selects between Centigrade (°C) and Fahrenheit (°F) D.
  • Page 4: Battery And Channel Installation: Remote Unit

    3. Place the main unit as close as possible next to the remote unit, reset the main unit after installing batteries. This will ensure easier synchronization between the transmission and reception of signals. 4. Position the remote unit and main unit within effective transmission range, which, in usual circumstances, is 20 to 30 meters.
  • Page 5: How To Use The Table Stand Or Wall Mounting

    HOW TO USE THE TABLE STAND OR WALL MOUNTING The main unit has a removable table stand, which when connected, can support the unit on a flat surface. Or you can remove the stand and mount the unit on a wall using the recessed screw hole. As for the remote unit, it comes with a wall-mount holder and a removable stand.
  • Page 6: Getting Started

    Remote unit GETTING STARTED Wall-mount Table Stand Once batteries are placed in a given remote sensor unit, it will start transmitting information at 40-second intervals. Also, for approximately a 3-minute duration, the main unit will automatically search for signals once batteries are installed. Upon successful reception, the individual channel temperature reading will be displayed on the top line and the respective humidity reading on the bottom line.
  • Page 7: How To Check Remote And Indoor Temperature & Humidity

    HOW TO CHECK REMOTE AND INDOOR HOW TO READ THE TEMPERATURE & HUMIDITY KINETIC WAVE DISPLAY Display of readings from a remote sensor or the main unit is a 1- The kinetic wave display shows the signal receiving status of the step procedure.
  • Page 8: Remote Sensor Scanning

    TEMPERATURE AND REMOTE SENSOR SCANNING HUMIDITY TREND INDICATORS The unit can be set to automatically scan and display readings from the remote sensors and indoor readings. When the remote-sensor The temperature-trend and humidity-trend indicators show the mode is active, the display will show the readings from one channel trends of collected readings.
  • Page 9: How To Use Channel-1 Temperature/Humidity Alarm

    2. Press L to set the temperature or humidity limit. Each press To clear the memory: will increase increments by degree or percentage. Press and • Press and hold MEMORY for 2-seconds. hold the button for a rapid-scrolling sequence by increments If you press MEMORY now, the maximum and minimum of 5.
  • Page 10: Transmission Collision

    (TEMP % RH AL) CALENDAR CLOCK DISPLAY MODES the alarm sound will stop. The RMR132HG supports four display modes in the sequence of: DISCONNECTED SIGNALS MODE 1. Local Time If without obvious reasons the display for a particular channel goes blank, press IN/CHANNEL &...
  • Page 11: About Radio Reception

    Day, Month calendar clock once it is brought within range of the Frankfurt DCF77 radio signal. When the RMR132HG is within range, its radio-control mechanism will override all manual settings. When the unit is receiving radio signal, the radio reception signal will start to blink.
  • Page 12: How To Set The Clock Manually

    For the second time zone, which is indicated by the ZONE ICON, enter the hour offset using the[L] or [M]buttons and the RMR132HG will calculate the second time accordingly. If there is an item you do not wish to change, simply press [SET/MODE] to bypass the item.
  • Page 13: How To Stop An Alarm

    HOW TO STOP AN ALARM TIME ZONE AND OFFSET TABLE To stop an alarm, you can use either [24 hr OFF / ((•))] or [AL ON/OFF]. To stop an alarm from ringing on the same day, press [24HR OFF / ((•))] or [AL ON/OFF ] once. Note that the alarm is still armed and will go off at the set time the following day.
  • Page 14: About Oregon Scientific

    (E, D, F, I) We hope you will find all the information you need on our website, Second time zone with date and day however if you'd like to contact the Oregon Scientific Customer Care department directly, please visit www2.oregonscientific.com/ 2-minute crescendo alarm service/support or call 949-608-2848 in the US.
  • Page 15: Ec Declaration Of Conformity

    Additional information: EC-DECLARATION OF CONFORMITY The product herewith complies with the requirements of the Low Voltage Directive 73 / 23 / EC, the EMC Directive 89 / 336 / EC This product contains the approved transmitter module that com- and carries the CE marking accordingly. plies with the essential requirements of Article 3 of the R&TTE 1999 / 5 / EC Directive, if used as intended and the following stan- dards have been applied:...