Tunturi j6f Service Manual page 25

Hide thumbs Also See for j6f:
Table of Contents

Advertisement

_____________________________________________________________________________________
Codes in connection with processing EEPROM memory.
The error codes below (40 – 65) are connected to problems of internal data transfer. If such a
code appears, reset the code and try to repeat the error. In case the code appears regularly,
replace the control board. Codes marked with an asterisk (*) are connected to save procedures of
memory, which can be repeated after resetting by pressing again the OK key. It is also possible to
move to another mode with the mode keys (e.g. MANUAL).
Number
40
41
42
43
44
45
46
47
48
49
50
51
52
53 * Failure in saving the target pulse.
54
55 * Failure in saving the number / intensity level of the latest profile.
56
57 * Failure in saving the user information.
58
59 * Failure in saving the self made profile.
60
61
62
63
64
65
Copyright by Tunturi Oy Ltd
SERVICE MANUAL
Error
EEPROM circuit does not answer to its address. The connection between the
processor and eeprom is cut. Restart the treadmill: if the error is repeated, replace the
control board.
EEPROM circuit is empty. The circuit is pre-programed with the ROM chart values.
This error appears always, when the treadmill is started for the first time. The
EEPROM circuit can also become empty / mixed for example due to a current peak,
resulting in the same error. The code can be removed with the RESET key, and the
treadmill can be used normally.
Configuration values are read as faulty and replaced with default values. Check
configuration in the Service Menu. E42 may appear only after net reset, when the
settings of the Service Menu are transferred to the operation memory. The treadmill
can be used normally. In case the same error appears several times repeatedly in a row,
replace the control board.
Failure in saving configuration values. The error may appear only in Service mode when
changing the configuration values. Repeat the save by pressing the OK key.
Max. pulse number of the lift motor read as faulty. Re-calibrate.
Failure in saving the max. pulse number of the lift motor. Repeat calibration.
Failure in reading the selected display mode.
Failure in saving the selected display mode.
Failure in reading the user selected elevation.
Failure in saving the user selected elevation.
Failure in reading the pulse value corresponding to the user selected elevation.
Failure in saving the pulse value corresponding to the user selected elevation.
Failure in reading the target pulse.
Failure in reading the number / intensity level of the latest profile.
Failure in reading the user information.
Failure in reading the self made profile.
Failure in reading the CUSTOM START target elevation / speed.
Failure in saving the CUSTOM START target elevation / speed.
Failure in reading the cumulative total distance.
Failure in saving the cumulative total distance.
Failure in reading the cumulative total time.
Failure in saving the cumulative total time.
TUNTURI
24
Version 1/2000
All information subject to changes

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

J8J6J8f

Table of Contents