Ac Power Supply Replacement; Dc Power Supply Installation - Dell Networking S4048 Installation Manual

Hide thumbs Also See for Networking S4048:
Table of Contents

Advertisement

b
Slot
When you install the PSU correctly, it snaps into place and is flushed with the back of the switch.
4
Plug in the appropriate AC three prong power cord from the switch PSU to the external power source.
5
If you have a redundant PSU, a second PSU, repeat steps 1 through 4 above using the second PSU slot on the S4048-ON system.
NOTE:
The S4048-ON powers up when the cables are connected between the power supply and the power source.

AC power supply replacement

CAUTION:
Disconnect the power cord before removing the power supplies. Also, disconnect all power cords before servicing.
NOTE:
The PSU slides into the slot smoothly. Do not force a PSU into a slot as this action may damage the PSU or the S4048–
ON chassis.
NOTE:
If a PSU fails, you must replace the entire unit. There are no field serviceable components in the PSU. To request a
hardware replacement, refer to
NOTE:
If you use a single PSU, install a blank plate in the other PSU slot. If you are only using one power supply, Dell
recommends installing the power supply in the first slot (PSU1) and installing a blank plate in the second slot (PSU2).
1
Disconnect the power cable from the PSU.
2
Use the grab handle to slide the PSU out of the power supply bay.
3
Use the grab handle on the replacement PSU to slide it into the power supply bay.
4
Attach the power cord to the replacement PSU.
NOTE:
The system powers up when the cables are connected between the power supply and the power source.

DC power supply installation

CAUTION:
To prevent electrical shock, ensure that the S4048-ON is grounded properly. If you do not ground your equipment
correctly, excessive emissions may result. Use a qualified electrician to ensure that the power cables meet your local electrical
requirements.
WARNING:
The system must have either AC power supplies or DC power supplies. You cannot mix power supplies.
NOTE:
The PSU slides into the slot smoothly. Do not force a PSU into a slot as this action may damage the PSU or the S4048-
ON chassis.
NOTE:
If you use a single PSU, install a blank plate in the other PSU slot. If you are only using one power supply, Dell
recommends installing the power supply in the first slot (PSU1) and installing a blank plate in the second slot (PSU2).
NOTE:
ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when
handling the S4048–ON and its components.
NOTE:
If a PSU fails, you must replace the entire unit. There are no field serviceable components in the PSU. To request a
hardware replacement, contact Technical Support at
Technical
Support.
www.dell.com/support.
Power supplies
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents