Leakage Test - Stihl MS 240 Instruction Manual

Hide thumbs Also See for MS 240:
Table of Contents

Advertisement

1
Check that the sleeve (2) and
washer (1) are in place.
The throttle rod must be attached to
the carburetor.
1
– Push the carburetor into position.
– Make sure the stub (1) slips into
the impulse hose (arrow).
1
: Push the fuel hose (1) on to the
stub (arrow).
86
Versions with handle and
carburetor heating
2
1
: Fit the heating element (1) and
heating plate (2).
– Fit the nuts and tighten them
down firmly.
– Position the wires, b 15.8
: Push the connector (1) on to the
contact spring (arrow) as far as
stop.
2
: Attach the throttle rod (1) to the
trigger (2).
– Fit the handle molding, b 12.2
– Check operation.
2
– Reassemble all other parts in the
reverse sequence.
– Tightening torques, b 3.5
14.3
In the case of problems with the
carburetor or fuel supply system,
also check and clean or replace the
tank vent, b 14.7
The carburetor can be tested for
leaks with the pump 0000 850 1300.
– Remove the carburetor, b 14.2
1
: Push the fuel hose (1)
1110 141 8600 on to the
nipple (2) 0000 855 9200.
1

Leakage Test

2
1
MS 240, MS 260, MS 260 C

Hide quick links: