JVC LT-26WX84 Service Manual page 27

Lcd flat television
Hide thumbs Also See for LT-26WX84:
Table of Contents

Advertisement

4.6
INITIAL SETTING VALUES IN THE SERVICE MODE
• Perform fine-tuning based on the "initial values" using the remote control when in the Service mode.
• The "initial values" serve only as an indication rough standard and therefore the values with which optimal display can be achieved
may be different from the default values. But, don't change the values that are not written in "ADJUSTMENT PROCEDURE". They
are fixed values.
NOTE:
As for the items whose settings are "Fixed" in Table 1 in "3.3 MEMORY IC REPLACEMENT", the following tables show initial
values in NTSC signal input mode. As for the items whose conditions of SETTING VALUE are not written in the following tables,
the following tables show initial values in NTSC signal input mode.
4.6.1 [1.PICTURE/SOUND]
Item
Item
No.
A01
(Not display)
A02
(Not display)
A03
(Not display)
A04
(Not display)
A05
(Not display)
A06
(Not display)
A07
(Not display)
A08
(Not display)
A09
(Not display)
A10
(Not display)
A11
(Not display)
A12
(Not display)
A13
(Not display)
A14
(Not display)
Item
Item
No.
S01 COLOR
S02 TINAD
S03 OF COLOR
S04 OF TINAD
S05 BRIG
S06 CONT
S07 OF BRIG
S08 OF CONT
S09 BYGN
S10 OF BYGN
S11 RYAXIS
S12 MIX
S13 RDRV
S14 RDRV
S15 GDRV
S16 GDRV
S17 BDRV
S18 BDRV
S19 CUTR
Variable
Setting value
range
000~007
001
000~007
001
000~007
001
000~007
000
000~015
003
000~015
004
000~015
006
000~015
003
000~007
006
000~007
004
000~063
063
000~063
063
000~003
000
000~007
000
Variable
NTSC
range
STANDARD THEATER STANDARD THEATER STANDARD THEATER STANDARD THEATER
000~255
163
122
-127~128
000
000
-127~128
000
000
-127~128
000
000
000~255
048
060
000~255
126
126
-127~128
000
000
-127~128
000
000
000~255
133
117
-127~128
000
000
-127~128
+006
000
000~003
000
000
000~255
255
255
-127~128
000
000
000~255
254
-127~128
000
-038
000~255
255
255
-127~128
000
-043
000~255
128
128
Item
Item
No.
A15
(Not display)
A16
(Not display)
A17
(Not display)
A18 IN LEVEL
A19 LOW SEP
A20 HI SEP
A21
(Not display)
A22
(Not display)
A23
(Not display)
A24
(Not display)
A25
(Not display)
A26
(Not display)
A27
(Not display)
Setting value
525i
163
121
000
000
000
000
000
000
048
060
126
126
000
000
000
000
125
116
000
000
+006
000
000
000
255
255
000
000
254
254
254
000
-038
255
255
000
-043
128
128
Variable
Setting value
range
000~003
000~003
000~003
000~015
000~063
000~063
000~001
(Not used)
000~001
(Not used)
000~001
(Not used)
000~001
(Not used)
000~001
(Not used)
000~001
(Not used)
000~001
(Not used)
525p
750p/1125i
163
124
155
000
000
000
000
000
000
000
000
000
048
060
036
126
126
128
000
000
000
000
000
000
125
116
147
000
000
000
+006
000
000
000
000
001
255
255
246
000
000
000
254
254
255
000
-038
000
255
255
225
000
-043
000
128
128
128
(No.YA089)1-27
000
000
000
007
026
063
146
000
000
000
043
128
000
000
118
000
000
001
246
000
255
-027
225
-038
128

Advertisement

Chapters

Table of Contents
loading