v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 7978 and 1913 server," on page 29 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
114
Adapter read-only memory error.
129
Internal cache (L2) error.
151
Real-time clock error.
161
Real-time clock battery error.
Action
1. Reseat the adapter.
2. Replace the adapter.
1. (Trained service technician only) Reseat
microprocessor 1.
2. (Trained service technician only) Reseat
microprocessor 2 (if present).
3. (Trained service technician only) Replace the
following components one at a time, in the order
shown, restarting the server each time:
a. Microprocessor 1
b. Microprocessor 2 (if present)
c. System board
1. Reseat the battery.
2. Clear CMOS. See "System-board switches and
jumpers" on page 11 for more information about
how to clear CMOS.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. System-board battery
b. (Trained service technician only) System
board
1. Run the Configuration/Setup Utility program,
select Load Default Settings, and save the
settings.
2. Clear CMOS. See "System-board switches and
jumpers" on page 11 for more information about
how to clear CMOS.
3. Reseat the battery.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. System-board battery
b. (Trained service technician only) System
board