IBM x3550 Problem Determination And Service Manual page 163

Type 7978; type 1913
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 7978 and 1913 server," on page 29 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
011-xxx-001
Failed COM2 serial port test.
030-xxx-000
Failed internal SAS interface test.
035-285-001
Adapter communication error.
035-286-001
Adapter CPU test error.
035-287-001
Adapter local RAM test error.
035-288-001
Adapter NVSRAM test error.
035-289-001
Adapter cache test error.
035-292-001
Adapter parameter set error.
035-230-001
Battery low.
035-231-001
Abnormal battery temperature.
035-230-001
Battery status unknown.
035-xxx-snn
Failed hard disk drive with ID nn on RAID
adapter in slot s.
035-xxx-099
No adapters were found.
Action
1. Check the loopback plug that is connected to the
serial port.
2. (Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the system
board.
1. Update the RAID controller firmware.
2. Reseat the RAID controller.
3. Replace the RAID controller.
1. Update the RAID controller firmware.
2. Reseat the RAID controller.
3. Replace the RAID controller.
1. Update the RAID controller firmware.
2. Reseat the RAID controller.
3. Replace the RAID controller.
1. Update the RAID controller firmware.
2. Reseat the RAID controller.
3. Replace the RAID controller.
1. Update the RAID controller firmware.
2. Reseat the RAID controller.
3. Replace the RAID controller.
1. Update the RAID controller firmware.
2. Reseat the RAID controller.
3. Replace the RAID controller.
Replace the battery module of the RAID controller.
Replace the battery module of the RAID controller.
Replace the battery module of the RAID controller.
1. Check the system-error log and replace any
indicated failing devices.
2. Reseat the disk with ID nn on adapter in slot s.
3. Replace the disk with ID nn on adapter in slot s.
If an adapter is installed:
1. Reseat the adapter.
2. Check the adapter cables to be sure they are
secure.